9.1.4 Ambient data
Tabelle 22:
Ambient data
Temperature
Protection rating
Climate category
Pollution category
Minimum, maximum relative
humidity (non-condensing)
Mechanical resistance
Max. installation height
Discharge of static electricity
ESD resistance according to EN 61000-6-7
•
Criterion: according to IEC 61000-4-2
•
Test voltage: 4 kV/8 kV Contact/Air
Failure of the product due to contaminated air
The ambient air must be free of higher concentrations of acids, alkalis, corrosive agents,
salt, metal vapors and other electrically conductive impurities.
The devices must be installed in housings or installation spaces with a protection rating
of at least IP 54 according to DIN EN 60529.
ctrlX SAFETY | Device type SAFEX-C.12
Value 1
0 °C ... +50 °C during operation
IP 20 according to EN 60529,
IP00 connector
3K22 according to DIN EN
60721-3-3
2 according to DIN EN 60664-
1:2007
8 % ... 95 %
Shock resistance:
Vibration:
Free fall (shipping package)
≤ 3000 m above sea level
NOTE
DOK-XSAFE*-SAFEX-C.1XC-IT03-EN-P, Edition 03, Bosch Rexroth AG
41/83
Value 2
-40 °C ... +70 °C for storage
(without condensation)
1 g/m³ ... 29 g/m³
EN 61800-2, IEC 60721-3-3
Class 3M1; 19.6 m/s²
IEC 61131-2; 5-8.4 Hz with
3.5 mm amplitude; 8.4-150
Hz with 1 g peak
acceleration
1 m