Led Indications; Power-Up; Status Led; State-Of-Charge Leds - Morningstar ProStar MPPT Series Installation, Operation And Maintenance Manual

Solar charging system controller
Hide thumbs Also See for ProStar MPPT Series:
Table of Contents

Advertisement

4.4 LED Indications

KEY:
G = green
G - Y - R = flashing sequencially
Y = yellow
G / Y
R = red
G / Y - R = G and Y flashing together,
alternating with R flash

4.4.1. Power-up

Normal power-up: Status LED flashes G, then SOC LEDS
flash G - Y - R, sequentially, then SOC LEDs will indicate
battery charge status with one or two lit battery status LEDs.
Failed bootload: Status LED flashes G, then SOC LEDS
flash G - Y and stop on solid Y.

4.4.2 Status LED

The Status LED indicates charging status and any exist-
ing solar input error conditions. The Status LED is on when
charging during the day and off at night. The Status LED will
flash red whenever an error condition(s) exists. Table 4.4 lists
the Status LED indications.
Color
Indication
Off (with heart-
None
beat¹)
On Solid
Green
(with heart-
beat²)
Red
Flashing
On Solid
Red
(with heart-
beat
)
2
¹ heartbeat indication flickers the Status LED on briefly every 5 seconds
² heartbeat indication flickers the Status LED off briefly every 5 seconds
Table 4.4. Status LED Definitions
50
Operation
= flashing together
Operating
State
Night
Charging
Error
Critical Error
NOTES:
1) R flashing is generally a user addressable fault / error
2) R charging status LED ON with heartbeat blink OFF
every 5 secs is a critical fault that generally requires service.
See, "Solid Charging Status LED with Self-test (R-Y-G) SOC
Faults", in Section 5.1.

4.4.3 State-of-Charge LEDs

Battery SOC LED Indications are shown in Table 4-5 below:
Condition
Absorption
Float
[G / Y / R] x2 - G- G
Start EQ (push-button)
[G / Y / R] x2 - R - R
Stop EQ (push-button)
Equalize
SOC > 13.5V
13.5V > SOC > 13.0V
13.0V > SOC > 12.5V
SOC < 12.5V
Low voltage disconnect
warning
Low voltage disconnect
Table 4.5. Battery SOC LED Indications

4.5 Push-Button Use in Non-Metered Version

The version of the ProStar MPPT without meter display
features a push-button that operates as follows depending
on the DIP Switch 1 setting:
Normal Mode (DIP 1 OFF)
• Regardless of the DIP 7 setting, press and hold the push-
button for 5 seconds to initiate or stop an Equalization
(EQ).
ProStar MPPT Operator's Manual
Indication
G flash - every sec
G flash - every 2 secs
G flash - 2 / sec
G solid
G / Y solid
Y solid
Y / R solid
R flash - every sec
R solid
51

Advertisement

Table of Contents
loading

This manual is also suitable for:

Prostar ps-mppt-25Prostar ps-mppt-25mProstar ps-mppt-40Prostar ps-mppt-40m

Table of Contents