Rv-C Diagnostics (If Equipped) - Garnet SeeLeveL II 709 Series Installation Manual & User Manual

Holding tank monitor
Table of Contents

Advertisement

Check Signal Power Diagnostics
1. Press and hold the button for the tank to be
checked, the display will show the level for that
tank.
2. While continuing to hold down the button for
the tank, press the BATT button.
3. When the display shows "dIA", release the
buttons, the display will then change to showing
the signal power diagnostic.
4. This is indicated by a "P" showing on the left
digit, for example "P26" indicates a 26% signal
power. "P00" is 100%.
5. The signal power will show for 5 seconds. The
display will then change to showing the sender
height.
This is indicated by a small "h"showing on the
left digit, for example "h 6" indicates that the
sender has 6 receive segments.
6. After 5 seconds of showing the height, the
display will shut off.
SeeLeveL II 709 Series Display Manual
7 8
FRESH
Hold
LEVEL IN PERCENT
+
+
FRESH
BATT
Hold
d i A
LEVEL IN PERCENT
P 2 6
LEVEL IN PERCENT
h 6
LEVEL IN PERCENT
LEVEL IN PERCENT

RV-C Diagnostics (if equipped)

Here is a list of the messages broadcast over the RV-C bus:
FMI (Failure Mode Identifier) Table
1
Datum value before normal range
2
Datum value erratic or invalid
5
Open circuit, or output current below normal OPN
Grounded circuit, or output current above
6
normal
DIS or OFF
ERR, BOT, TOP, NTP, NBP,
or SIN
SHT
Page 13