02.9628.0010
7-Oct-97
CAUTION: Space for nutdriver is very limited, be careful not to break
diffuser panel during procedure.
c. Using 1/4 inch nutdriver, remove two 3-56 nylon insert stop
lock nuts that secure sensor to threaded standoffs and
remove sensor.
Step 4.
Prepare and install replacement sensor.
a. At replacement sensor assembly, using needle-nosed pliers,
bend unused sensor lead to 45° angle.
b. Trim sensor assembly wires to 21 inches.
CAUTION: To avoid poor connections, do not reuse MTA connector
from removed sensor on replacement sensor.
c. Using MTA crimper, crimp wires into new 4-pin MTA
connector using the following pinouts:
d. Install strain relief cover on 4-pin connector. Using
permanent ink marker, mark strain relief DIFF.
Note: During installation of sensor, make sure that sensor switch is
installed with microswitch pointing toward diffuser opening.
e. Install replacement sensor and re-install diffuser mechanism
by doing Steps 2 thru 5 in reverse.
C
3. M
HAPTER
Pin
Wire
4
Blue
3
Blue
2
N/C
1
N/C
P
AINTENANCE
ROCEDURES
3-43