VARILITE VL4 Manual page 65

Wash luminaire
Table of Contents

Advertisement

Table 3-9 General Error Codes
Error for PSU Test (15)
Error
NSC = Parameter
Number
LDC = Error Number
01
02
03
04
05
11
12
13
14
15
02.9628.0010
7-Oct-97
MSC = F
IPRES
PSOT
HOT
SHORT
NOT IPRES
C
3. M
HAPTER
Error for Mechanics
Tests (1 to 11)
MSC = Test Number
NSC + LSC = Error
Number
No data activity error
Data activity error
No reset error
Count does not change
Bit count is not sequential Display received and
Sensor hit too early,
motion impeded
Backlash too small (0)
Backlash too large.
Sensor not hit, motion
impeded, sensor
permanently high
Sensor permanently low
P
AINTENANCE
ROCEDURES
Results Associated With
Mechanics Error Codes
(After Error Code)
Display count last seen
expected count
Indicate backlash value
(half steps in
hexadecimal)