Intermec CN51 User Manual page 27

Hide thumbs Also See for CN51:
Table of Contents

Advertisement

Field Definitions for MobileDocumentImaging_Config.xml (continued)
Field Name
ColorModeBrightness
Threshold
allowChanges
colorModeBrightness
File Index Information
allowIndexInformation
Changes
includeTextFile
field where is 1-5
entryRequired
minLength
maxLength
Enhanced Mobile Document Imaging (eMDI) User Guide
Valid Values
Description or Notes
True or false
Allows or restricts the user from adjusting the
Color Mode Brightness Threshold setting.
Default is false.
Very dark, dark,
Sets the brightness threshold. Default is no
normal, bright, or
value.
very bright
Disabled, optional,
If File Index Information is disabled, the option
or required.
to input information is not offered in the
application.
If File Index Information is optional, there is a
menu item in the Options menu to enter index
information.
If File Index Information is required, the screen
to input index information is displayed in the
application before the Capture screen, and the
user is forced to enter information set up as
required.
True or false
If this is set to true, a text file with the same
name as the image is created. In the text file is
the index information.
Character string
If no fields are set,
up to 50
allowIndexInformationChanges should be set
characters.
to disabled. This is used in the
FileNameTemplate in the $(field ). Users can
also include fields to be use in the
FileNameTemplate, but set the
allowIndexInformationChanges to false. If this
is the case, eMDI uses the values supplied in
defaultValue.
True or false
If it is set to true, the user must enter
something before leaving the screen if a default
is not set. Default is false.
Numeric
Default is zero if not required. If entryRequired
is true, the default is one.
Numeric
Specifies the number of characters the user can
enter. Default is 30.
27

Advertisement

Table of Contents
loading

Table of Contents