Page 1
DC/AC Fuel Transfer Pumps Instruction Manual WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious personal injury. Save these instructions in a safe place and on hand so that they can be read when required. Keep these instructions to assist in future servicing.
GENERAL SAFETY REGULATIONS WARNING: The warnings, cautions, and instructions discussed in this instruction manual cannot cover all possible conditions or situations that could occur. It must be understood by the operator that common sense and caution are factors that cannot be built into this product, but must be supplied by the operator.
Page 3
Auto 17530764 EXDFP120-001 120V Up to 15/57 Auto 17330573 FTP120-001 120V Up to 20/76 Auto 17330762 * Use an automatic nozzle and/or filter will reduce flow rate. These products are positive displacement, rotary vane pumps. Depending on installation and viscosity, these pumps can deliver up to 20GPM or 76 LPM. Their rugged design makes for a long life of dependability.
OPERATION OPERATING CONDITIONS • Temperature: min -20°C/max +40°C (-4°F /max 104°F) • Relative Humidity: max 90% FLUID COMPATIBILITY • These products are compatible with the following fluids: Gasoline, Diesel, Kerosene & Mineral Spirits • Do NOT use with other fluids without consulting manufacturer. INSTALLATION 1.
PROBLEMS AND SOLUTIONS Problem Possible Cause Corrective Action The motor is not Lack of electric power Check the electrical connections and the safety systems turning Rotor jams Check for possible damage or obstruction of the rotating components. Motor problems Contact with the service department Thermal overload protection shut Move ON/OFF lever to the “OFF”...
Page 6
2. Macnaught’s liability is limited to replacement or repair of defective material within the warranty period, when returned freight prepaid to the distributor or their designated service depot.
Page 7
Part No. Description Q’ty Part No. Q’ty Description Screw Screw Rotor cover Switch Rotor Bracket Vane Bushing Spring Gasket O-ring Gasket Seal Seal Kit Shift folk Discharge hose O-ring Elbow Junction box cover Bypass spring Screw Electric motor Grounded screw Pump chamber Switch bracket Bypass valve...
Need help?
Do you have a question about the FTP120-001 and is the answer not in the manual?
Questions and answers