Appendix C: Installing The Fiber Module - Linksys Etherfast EF1704 User Manual

Layer 3 management 4-port gigabit ethernet switch instant etherfast series
Hide thumbs Also See for Etherfast EF1704:
Table of Contents

Advertisement

3. Change your baud rate to the selected value, and press Enter to enable
download. From the terminal emulation program, select the file you want
to download, set the protocol to XModem, and then initialize downloading.
Note: If you use Windows Hyperterminal, disconnect it. Set the baud rate,
and reconnect it.
Note: The download file should be a binary file or an image file; other-
wise, the agent will not accept it.
4. After the file has been downloaded, the console screen will display infor-
mation similar to that shown below. Press Enter to download to permanent
memory, and change the baud rate back to 19200. Press Enter to start
decompressing the new firmware, and then press Enter to open the Logon
screen.
XModem Download to 0x00400020: ... SUCCESS !
(P)ermanent or (T)emporary Download: [P]
Update RunTime Image at 0x03040000 ... ... SUCCESS !
Change to original Baud Rate and Press <ENTER> to Run
Application !!!
Decompress now...... !!!
run-time code starting now. !!! Starting System ...
MAINBOARD OCTOPUS0 RAMBIST TEST ...... PASS!
MAINBOARD OCTOPUS1 RAMBIST TEST ...... PASS!
MAINBOARD OCTOPUS2 RAMBIST TEST ...... PASS!
MAINBOARD OCTOPUS3 RAMBIST TEST ...... PASS!
MAINBOARD DOLPHIN
RAMBIST TEST ...... PASS!
MAINBOARD STARFISH RAMBIST TEST ...... PASS!
Press <Enter> to start UI
Your firmware has now been updated.
107
Instant EtherFast
Series
®
EtherFast
Layer 3 Management 4-Port Gigabit Ethernet Switch
®
Appendix C: Installing the Fiber
Module
You can increase the number of ports on the Switch from four to eight by
installing Fiber Modules on the Switch's four available slots.
To install the Fiber Modules do the following:
1. Power off the Switch.
2. Remove the Fiber Module's slot with a phillips screwdriver.
3. Slide the Module into the slot.
(See Figure C-1 or C-2,
depending upon the type of
module you use.)
4. Tighten the Module's thumb-
screws.
5. Connect a UTP Category 5e
(or better) cable.
6. Power on the Switch.
Figure C-1
Figure C-2
108

Advertisement

Table of Contents
loading

Table of Contents