NLTroubleshooting
Malfunction
"E:30 / -80"
"E:36 / -25 / -26"
"E:38 / -25 / -26"
"E:10 / -00 / -10 /
- 20"
46
Cause and Troubleshooting
When dosing manually, reduce the amount of
▶
detergent for the next wash with an equal load.
Unauthorized extension mounted on the water drain
hose.
Remove any unauthorized extensions from the
▶
water drain hose.
→
"Connecting the device", page 16
Pump cover is not fully screwed in.
Make sure that the pump cover is screwed into the
▶
device as far as it will go. The pump cover handle
must be vertical.
Drain pump is clogged.
→
"Cleaning the drain pump", page 42 .
▶
Drain pump is clogged.
→ "Cleaning the drum", page 40
▶
if the fault is displayed again,
→
"Cleaning the drain pump", page 42
▶
Inlet opening of the rubber sleeve is clogged.
→ "Clean the inlet opening in the rubber sleeve",
▶
page 44
Pump of the intelligent dosing system is blocked.
Switch off the device.
1.
Clean the pump unit.
2.
→ "Cleaning the detergent drawer", Page
40
Switch on the device.
3.
If the indication reappears after cleaning the pump
4.
unit, call the service.
→
"Customer Service", page 59
Remark:Until the fault has been rectified, you can
deactivate the intelligent dosing system and dose
manually.
→ "Buttons", Page 25