6.4
Modbus TCP to Modbus RTU over 4G / 5G, and card reader
monitor
After completing the following steps, please set the "IP:Port" of the Modbus TCP program to
"127.53.0.1:10001" in your control center (port 10001 is RS-232; port 10002 is RS-485)
(1) Please connect your device (M-7017 or PLC) to RS-485 of GRP device.
 The baudrate of Modbus device is 9600
 The baudrate of Card Reader
(2) Open VxServer and VxComm Utility software.
For more information about VxServer, please refer to
http://www.icpdas.com/en/product/guide+Software+Applications+VxServer
(3) If necessary, fill in "PIN Code", "APN", "User Name" and "Password". After finishing all
the settings, click "Modify".
GRP-2841M User Manual
Copyright © 2022 ICP DAS Co., Ltd. All Rights Reserved
bps and the data format is 8N1.
is 115200 bps and the data format is 8N1.