ATTENTION!
During the saving procedure the device is not accessible over a period of a few milliseconds.
10.2.8 Setting the Baud Rate
1. Change the device into the Stopped mode ( 10.2.6.3)
2. Change the device into the LSS Configuration Mode ( 10.2.7.1)
3. Change baud rate according to the following command:
Master
Adjusting the baud rate
Values for XX:
0 = 1 MBit/s
1 = 800 kBit/s
2 = 500 kBit/s
Figure 27: Setting the baud rate
4. Save parameter as described in section ( 10.2.7.2).
5. Turn the device off and restart it again.
10.2.9 Setting the node-ID
1. Change the device into the Stopped Mode ( 10.2.6.3)
2. Change the device into the LSS Configuration Mode ( 10.2.7.1)
3. Change node-ID with the following message:
Master
Changing the node-ID
XX = new node-ID in the range 01h .. 7Fh
Figure 28: Setting the node-ID
4. Save parameter as described in section ( 10.2.7.2).
5. Turn the device off and restart it again.
ID:
7E5
DLC:
13
00
XX
00
00
3 = 250 kBit/s
4 = 125 kBit/s
5 = reserved
ID:
7E4
DLC:
13
00
00
00
00
ID:
7E5
DLC:
11
XX
00
00
00
ID:
7E4
DLC:
11
00
00
00
00
CANopen
device
8
00
00
00
6 = 50 kBit/s
7 = 20 kBit/s
8 = 10 kBit/s
8
00
00
00
CANopen
device
8
00
00
00
8
00
00
00