Description Installation Of The Sensor - ELGO Electronic LIMAX2 Series Operating Manual

Magnetic absolute shaft information system for elevators
Table of Contents

Advertisement

Installation and First Start-Up
9.2

Description installation of the Sensor

9.2.1
Installation Principe
Upper tape fixation
Upper tape fixation
Sensor
Sensor
Magnetic tape
Magnetic tape
Guide rail
Guide rail
Sway guard
Spring
Tension weight
Figure 6: Installation with tension weight
Figure 7: Installation with dowel and spring
LIMAX2 can be installed at any position in the shaft, depending on spatial conditions and layout of the particular
elevator installation.
The magnetic tape is installed freely suspended in the shaft. It can be fixed with the RMS mounting kit (available
as option) on the guide rail. Alternatively fixation in the shaft head is either on beams or directly bolted into the
ceiling. The necessary tension in the tape is provided by a tension weight of about 5 kg. A sway guard at the
bottom will keep the tape from swaying in an uncontrolled position. Alternatively the magnetic tape can be ten-
sioned by a spring.
The sensor head can be mounted onto the cabin or cabin frame, depending on the spatial conditions of the
elevator.