Circuit Protectors; Remove Contents From Carton; Battery Cable Connection (If Equipped) - Generac Power Systems iQ3500 Owner's Manual

Hide thumbs Also See for iQ3500:
Table of Contents

Advertisement

Available languages

Available languages

Circuit Protectors

The AC receptacles are protected by an AC
circuit protector. If the generator is overloaded
or an external short circuit occurs, the circuit
protector will trip. If this occurs, disconnect all
electrical loads to determine the cause of the
problem before using the generator again.
Reduce the load if the circuit protector is
tripped.
NOTE: Continuous tripping of the circuit pro-
tector may cause damage to generator or
equipment.
Push the button of the protector to reset the
circuit protector.

Remove Contents from Carton

1. Open carton completely by cutting each
corner from top to bottom.
2. Remove and verify carton contents prior to
assembly. Carton contents should contain
the following:
Accessories
Item
Main Unit
Owner's Manual
Engine Oil
Oil Funnel
Tool Kit
Service Warranty
Emissions Warranty
3. Call Generac Customer Service at 1-888-
GENERAC (1-888-436-3722) with the unit
model and serial number for any missing
carton contents.
4. Record model, serial number, and date of
purchase on front cover of this manual.
8
Figure 2-9. Instruction Action Label
Qty.
1
1
1
1
1
1
1
Battery Cable Connection (if
equipped)
Equipment damage. Do not make battery
connections in reverse. Doing so will result
in equipment damage.
The unit has been shipped with the battery
cables disconnected.
See
Figure
2-10.
1. Use a Phillips screwdriver to remove the
screw from the battery door.
2. Remove battery strap (1) from battery (2).
Figure 2-10. Battery Connection
3. First, connect the red cables to the positive
(+) battery terminal with the bolt and nut
supplied.
4. Make sure connections are secure and
slide rubber boot over the positive (+) bat-
tery terminal and connection hardware.
5. Connect the black cables to the negative
(-) battery terminal with the bolt and nut
supplied. Slide rubber boot over the neg-
ative (-) battery terminal and connection
hardware.
6. Make sure all connections are secure.
Owner's Manual for Portable Generator
CAUTION
(000167a)
014561
1
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents