Error Diagnostics; What To Do In Case Of Failure; Diagnosis; Transmitter Diagnosis - Leuze electronic SOLID-2SF-M Original Operating Instructions

Optoelectronic delivery guarding for sheet fed offset printing machines
Hide thumbs Also See for SOLID-2SF-M:
Table of Contents

Advertisement

Error diagnostics

7
Error diagnostics
The following information is used for rapid troubleshooting in case of failure.
7.1

What to do in case of failure?

If the AOPD shows an error on the display, the machine must be stopped immediately and checked by
competent personnel. If it is determined that the error cannot be clearly defined and remedied, your local
Leuze office and/or the Leuze hotline can assist.
7.2

Diagnosis

Operating faults often have simple causes that you can remedy yourself. The following tables provide
detailed assistance.
7.2.1

Transmitter diagnosis

LED indicator
LED1 does not illuminate Check supply voltage and connection cable, replace transmitter if necessary
LED1 illuminates red
continuously
Table 7.1:
7.2.2

Receiver diagnosis

The receiver distinguishes between error codes (E xx) and fault codes (F xx). Only error codes (E) provide
information about events or states that you can remidy. If the receiver shows a fault code (F), it must be
replaced. Consequently, only error codes (E) are shown below:
Code
8
F xx
E 00
E 01
E 06
E 07
E 14
E 18
E 22
Table 7.2:
Leuze electronic GmbH + Co. KG
Measure for troubleshooting
Check the test input, hardware error, replace transmitter
Transmitter diagnosis
Cause/meaning
LEDs and 7-segment display do not illumi-
nate
Illuminates continuously/hardware error
Internal hardware error
Source of interference in the ambient area
Cross-circuit between two SSDs or
between SSD and Dyn SSD
Short-circuit of an SSD against GND or
cross-circuit between two SSDs or between
SSD and Dyn SSD
Short-circuit of an SSD against +24V DC or
cross-circuit between two SSDs or between
SSD and Dyn SSD
Undervoltage at the supply line
Test time limit exceeded
Overvoltage at the supply line
Receiver diagnosis
Measure for troubleshooting
Check the 24V DC supply voltage and the
connection cable; replace receiver if neces-
sary
Replace receiver
Replace receiver
Eliminate the source of interference
Rectify short-/cross-circuit
Rectify short-/cross-circuit
Rectify short-/cross-circuit
Check/replace power supply unit or load
Test time > 150 ms; check external testing
Check power supply unit/load
SOLID-2SF-M
21