7-Segment Display; Led Indicators - Leuze electronic SOLID-2SF-M Original Operating Instructions

Optoelectronic delivery guarding for sheet fed offset printing machines
Hide thumbs Also See for SOLID-2SF-M:
Table of Contents

Advertisement

Display elements
4.2.1

7-segment display

After the supply voltage is switched on, the following data appears on the 7-segment display of the
receiver:
7-segment display
1 or 2
Table 4.2:
7-segment display
E xx
F xx.
1 or 2 flashing
Table 4.3:
4.2.2

LED indicators

LED indicators for the receiver
LED
Color
LED1
Red/
green
Table 4.4:
Leuze electronic GmbH + Co. KG
Meaning
Permanent display after startup
Display of the transmission channel 1 or 2
7-segment display, receiver, permanently
Meaning
Temporary event displays, 1 s per display
Display of locking status "Error", which can be rectified by the user; E xx =
Error code (see chapter 9). The display shows E, 3 (1st position) and 0 (2nd
position) alternating, and then repeats this sequence
Display of locking status "device error" and internal error code. Receiver
must be replaced
Flashing transmission channel number -> weak signal display, device not
optimally aligned or soiled
7-segment display, receiver, temporary
Meaning
Red
= At least one safety output SSD in OFF state
Green
= All safety outputs SSDs in the ON state
No display = Device without supply voltage