SECTION II: Troubleshooting Tips

2.1 Power/Electrical Issues
The General Service Information Manual provides directions for removing shrouds to access the inside of the unit.
Issue
No power to the console.
If power is not restored to the console after all the connections have been checked and secured, you may need to
replace the console itself. Refer to Section III for more information.
Units with controller mounted near the floor.
Figure 2.4
Possible Cause
Loose or improper plug-in at
wall or unit.
Loose or improper electrical
connections within unit.
What to Do
Check that the power supply is properly and
securely plugged in to a working AC power
outlet (wall plug-in).
Check that the power supply cord is properly
and securely inserted into the power input jack
located below the right roller track (Figure 2.1).
Unplug the machine, then remove the four (4)
screws securing the console to the console
upright tube.
Unplug and re-plug the cable into the console to
ensure it is a good connection (Figure 2.2).
Check and secure the upper wire harness
connections, at the base of the upright post
(Figure 2.3).
Check and secure the lower wire harness
connections at the controller board and the
servomotor (Figure 2.4).
Plug in the machine to verify power to the
console.
Units with controller mounted above flywheel