Issue
"Err6", "Err7", "Err8", or "Err9"
is displayed on the console,
indicating limit switch issues.
"Err11" is displayed on
the console, indicating a
communications issue.
Console buttons are not
responding or are sticking.
Possible Cause
Faulty limit switch assembly
on stride motor.
Faulty wiring harness.
Faulty console key.
What to Do
Unplug the unit.
If the unit is new (that is, just out of the box),
unplug and re-plug the limit switch assembly at
the stride motor (Figure 2.30) to ensure a good
connection.
If the unit is not new and has previously been
working without displaying these errors, check
the plug-in for the limit switch assembly (Figure
2.30). If it is connected, disconnect it and plug
in a new limit switch and test. If the error is
resolved, complete the installation of the new
limit switch according to the directions in Section
III.
Unplug the machine. Unplug and re-plug
all connections to the controller board and
servomotor (Figure 2.31, older units, or Figure
2.32, newer units.).
If the issue is not resolved, you will need to
replace the wiring harness according to the
directions in Section III.
Replace the keypad overlay according to the
directions in Section III.
Q45 2.3