Download Print this page

HP E2492A Installation Manual

Probe adapter for the intel deschutes processor

Advertisement

Quick Links

About this Manual
We've added this manual to the Agilent website in an effort to help you support
your product. This manual is the best copy we could find; it may be incomplete
or contain dated information. If we find a more recent copy in the future, we will
add it to the Agilent website.
Support for Your Product
Agilent no longer sells or supports this product. Our service centers may be able
to perform calibration if no repair parts are needed, but no other support from
Agilent is available. You will find any other available product information on the
Agilent Test & Measurement website, www.tm.agilent.com.
HP References in this Manual
This manual may contain references to HP or Hewlett-Packard. Please note that
Hewlett-Packard's former test and measurement, semiconductor products and
chemical analysis businesses are now part of Agilent Technologies. We have
made no changes to this manual copy. In other documentation, to reduce
potential confusion, the only change to product numbers and names has been in
the company name prefix: where a product number/name was HP XXXX the
current name/number is now Agilent XXXX. For example, model number
HP8648A is now model number Agilent 8648A.

Advertisement

loading

Summary of Contents for HP E2492A

  • Page 1 Agilent Test & Measurement website, www.tm.agilent.com. HP References in this Manual This manual may contain references to HP or Hewlett-Packard. Please note that Hewlett-Packard's former test and measurement, semiconductor products and chemical analysis businesses are now part of Agilent Technologies. We have made no changes to this manual copy.
  • Page 2 Installation Guide Publication number E2492-92000 December 1997 © Copyright Hewlett-Packard Company 1997 All Rights Reserved HP E2492A Probe Adapter for the Intel Deschutes Processor...
  • Page 3: Installation At A Glance

    Intel Deschutes processors. This probing system provides a quick and reliable connection from a Deschutes processor to the HP E2487A Preprocessor Interface. The probe adapter contains equipment and procedures for connecting to both slot 1 and slot 2 Deschutes processors.
  • Page 4: Equipment Supplied

    Equipment Supplied • Bottom clamp • Interposer • Probe head • Fan and heat sink assembly • Front-side cache heat sink assembly (required for slot 2 processors) • Back-side cache heat sink assembly (required for slot 2 processors) • Slot 1 card guides (2) •...
  • Page 5 Minimum Equipment Required • A target system with the processor card removed from the S.E.C. cartridge. Detailed instructions for disassembling the S.E.C. cartridge can be found in Intel’s S.E.C. Cartridge Disassembly Application Note.
  • Page 6 To disassemble the slot 1 S.E.C. cartridge To disassemble the slot 1 S.E.C. cartridge The slot 1 S.E.C. cartridge consists of a thermal plate, skirt, cover, and processor card. The thermal plate, skirt, and cover must be removed to access the processor card. Detailed instructions for disassembling the slot 1 S.E.C.
  • Page 7 To disassemble the slot 1 S.E.C. cartridge Using the instructions in the Intel S.E.C. Cartridge Disassembly Application Note, insert a 1/8" small flat blade screwdriver between the cover and the thermal plate, next to one of the four barbed posts located at each corner of the thermal plate.
  • Page 8 To disassemble the slot 2 S.E.C. cartridge To disassemble the slot 2 S.E.C. cartridge The slot 2 S.E.C. cartridge consists of a thermal plate, skirt, cover, and processor card. The thermal plate, skirt, and cover must be removed to access the processor card. Detailed instructions for disassembling the slot 2 S.E.C.
  • Page 9 To disassemble the slot 2 S.E.C. cartridge Using the instructions in the Intel S.E.C. Cartridge Disassembly Application Note, insert a 1/8" small flat blade screwdriver between the cover and the thermal plate, next to one of the four barbed posts located at each corner of the thermal plate.
  • Page 10 To connect to the slot 1 Deschutes target system To connect to the slot 1 Deschutes target system The Deschutes probe adapter connects to the slot 1 processor card once the processor card has been removed from the S.E.C. cartridge. Slot 1 Connection Overview...
  • Page 11 To connect to the slot 1 Deschutes target system To prevent equipment damage, remove power from the target system. Install the interposer on the microprocessor on the processor card. The alignment tabs on the interposer aid in making proper alignment. Ensure that pin A1 is oriented correctly (see figure below).
  • Page 12 To connect to the slot 1 Deschutes target system Loosen the screw on the underside of the bottom clamp. Work the four clamp posts of the bottom clamp through the holes in the processor card. Aligning the Slot 1 Clamp Posts...
  • Page 13 To connect to the slot 1 Deschutes target system Place the probe head onto the interposer using the three alignment pins of the interposer and the three alignment holes of the probe head as shown in the figure below. Alignment Pins Placement Move the top sliding clamp forward on the probe end until it holds the clamp posts of the bottom clamp.
  • Page 14 To connect to the slot 1 Deschutes target system Insert the heat sink into the rectangular opening on top of the preprocessor interface. Tighten the two screws until the heat sink is snug. Do not over tighten. Connecting the Heat Sink Connect the heat sink fan to a +12 Volt power source.
  • Page 15 Deschutes probe package into the slot until the connector is fully seated. Slot 1 Final Connection Procedure You are now ready to connect the Deschutes probe to the HP E2487A Preprocessor Interface. Refer to the HP E2487A Preprocessor Interface User’s Guide for connection information.
  • Page 16 To connect to the slot 2 Deschutes target system To connect to the slot 2 Deschutes target system The Deschutes probe adapter connects to the slot 2 processor card once the processor card has been removed from the S.E.C. cartridge. Slot 2 Connection Overview...
  • Page 17 To connect to the slot 2 Deschutes target system To prevent equipment damage, remove power from the target system. Install the interposer on the microprocessor on the processor card. The alignment tabs on the interposer aid in making proper alignment. Ensure that the chamfered corner is oriented correctly (see figure below).
  • Page 18 To connect to the slot 2 Deschutes target system Loosen the screw on the underside of the bottom clamp. Work the four clamp posts of the bottom clamp through the holes in the processor card. Aligning the Slot 2 Clamp Posts...
  • Page 19 To connect to the slot 2 Deschutes target system Place the probe head onto the interposer using the three alignment pins of the interposer and the three alignment holes of the probe head as shown in the figure below. Alignment Pins Placement Move the top sliding clamp forward on the probe end until it holds the clamp posts of the bottom clamp.
  • Page 20 To connect to the slot 2 Deschutes target system Insert the heat sink into the rectangular opening on top of the preprocessor interface. Tighten the two screws until the heat sink is snug. Do not over tighten. Connecting the Heat Sink...
  • Page 21 To connect to the slot 2 Deschutes target system Move the probe head cables so the heat sink assembly fits against the front-side cache on the processor card. Connecting the Heat Sink Assembly to the Processor Card...
  • Page 22 To connect to the slot 2 Deschutes target system Use the spring clamps to fasten the front-side cache heat sink assembly to the front-side cache. Fastening the Front-Side Cache Heat Sink Assembly to the Front-Side Cache Use the spring clamps to fasten the back-side cache heat sink assembly to the back-side cache.
  • Page 23 To connect to the slot 2 Deschutes target system Connect the heat sink fan to the appropriate power sources. In the illustration below, the top four power leads require +5 Volts and the bottom power lead pair requires +12 Volts. For all lead sets, the black wire is ground, and the red wire is positive.
  • Page 24 S.E.C. slot until the connector is fully seated. Sliding the Assembled Deschutes Probe Package into the Slot You are now ready to connect the Deschutes probe to the HP E2487A Preprocessor Interface. Refer to the HP E2487A Preprocessor Interface User’s Guide for connection information.
  • Page 25: To Connect The Probe Adapter To The Hp E2487A Preprocessor Interface

    To connect the probe adapter to the HP E2487A Preprocessor Interface To connect the probe adapter to the HP E2487A Preprocessor Interface The probe adapter has five high-density connectors, labeled Cable P1 through Cable P5. The HP E2487A Preprocessor Interface also has five high-density cabled connectors, labeled P1 through P5.
  • Page 26: Power Requirements

    Assembly" program. This allows you to exchange a faulty assembly with one that has been repaired, calibrated, and performance verified by the factory. The cost is significantly less than that of a new assembly. Replaceable Parts HP Part Number Description E2492-60001 Probe Head...
  • Page 27 Probe dimensions (slot 1) Probe dimensions (slot 1) The figure below gives the dimensions for the slot 1 Deschutes Probe Adapter Assembly. The dimensions are listed in inches and millimeters.
  • Page 28 Probe dimensions (slot 2) Probe dimensions (slot 2) The figure below gives the dimensions for the slot 2 Deschutes Probe Adapter Assembly. The dimensions are listed in inches and millimeters.
  • Page 30 © Copyright Hewlett- Safety Warning Safety Symbols • Packard Company 1997 This apparatus has been Service instructions are for All Rights Reserved. designed and tested in trained service personnel. To accordance with IEC avoid dangerous electric Instruction manual symbol: Publication 348, Safety shock, do not perform any Reproduction, adaptation, or the product is marked with...
  • Page 31 About this edition for a particular purpose. This Hewlett-Packard system This is the first edition of the product is warranted against HP E2492A Probe Adapter Exclusive Remedies defects in material and for the Intel Deschutes workmanship for a period of...
  • Page 33 *E2492-92000* *E2492-92000* HP Part Number E2492-92000 Printed December, 1997...