7-1 Maintenance Items
Listed below are typical parts that require cleaning or replacement depending on the usage environment or duration of
service of the laser marker.
Some parts are maintainable by the customer, and other parts are required to be repaired or replaced by our service
representative, depending on the types of parts and the defects.
For purchasing replacement parts or requesting our service representative to repair or replace parts, contact our sales
agency.
Head
No.
Parts name
Protection glass of laser
q
emission port
Air filter
w
Air-cooling fan (Controller)
e
Exhaust vent
r
Laser oscillator
t
Galvano scanner
y
Internal shutter
u
Battery inside the controller
i
Contactor for interlock
o
Cable
1)
• Be sure to use our specified replacement parts. If the user applies any other fuses than the specified one, failure might
result.
u
y
q
Main cause for
degradation
Contamination
Contamination
Contamination
Contamination
Aging
Aging
Aging
Aging
Aging
Broken
ME-LPRF-SM-11
Controller
t
w
w
e
Daily maintenance
Cleaning
Cleaning
Cleaning
Cleaning
Check output power
―
―
―
―
―
o
1)
Replacement when degraded or
defective
Customer-replaceable
Customer-replaceable
Customer-replaceable
―
By our service representatives
By our service representatives
By our service representatives
Customer-replaceable
Customer-replaceable
Customer-replaceable
r
i
161