4-6-6 On-the-fly marking: Marking at regular intervals

SHUTTER OPEN OUT
(No.39)
READY OUT (Y5)
TRIGGER IN (X5)
PROCESSING OUT (Y10)
LASING OUT (No.40)
PROCESSING END OUT
(Y11)
*1 : If TRIGGER IN (X5) turns off when the trigger processing operation is running, on-the-fly marking at regular intervals
is terminated after finishing the running operation.
Item
Time
T1
T2
T3
T4
2 to 510ms
T5
• If the counter is reset during on-the-fly marking operation, there is a case that the next marking could not be executed
due to Warning E751.
ON (Open)
OFF (Close)
T1
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Remarks
Time for marking data creation. It varies depending on the quantity of the setting data.
Time from when TRIGGER IN (X5) is turned on till when the work piece comes to the
preset marking position.
Time it takes the workpiece to move to the setting intervals [mm].
This is the output to notify that the marking trigger processing completed normally. This is
One-shot output. Set the output time on System settings screen. There is a small margin of
error for the setting value.
Time for marking data creation.
When the next marking data is not ready during the marking operation, this is the rest time
for data creation.
When the next marking data is ready during the marking operation, this takes less than
1ms.
ME-LPRF-SM-11
T2
T3
T4
T5
*1
T3
T4
T4
113