4-6-10 Guide laser radiation input

SHUTTER ENABLE IN (X9)
SHUTTER IN (X8)
SELECT 0 - 2 IN (No.19-21)
GUIDE IN (No.23)
READY OUT (Y5)
SHUTTER CLOSE 1 OUT (Y8)
SHUTTER CLOSE 2 OUT (Y9)
Item
Time
T1
Max. 1 sec.
T2
0ms or more
T3
0.5ms or more
T4
Max. 60 sec.
*1 : Select the indication contents of the guide laser with SELECT 0 IN to SELECT 2 IN as follows.
Radiation details
Work distance
Marking image
Marking field
Masked objects
*2 : Keep the input state of SELECT 0 IN to SELECT 2 IN (No.19-21) while GUIDE IN (No.23) is turned ON.
• To use a guide laser in remote mode while any of the INTERLOCK inputs (REMOTE INTERLOCK IN, INTERLOCK
1, INTERLOCK 2) is open, set "Deactivate while shutter closed" in "System settings" > "Operation/information" >
"INTERLOCK alarm detection".
• If you have configured the guide laser control method of external control to communication commands by the system
settings of Laser Marker NAVI smart, the guide laser radiation by I/O is not possible.
• Do not execute any other operation while the guide laser is emitted.
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON (Close)
OFF (Open)
Remarks
There is a delay time of around 200ms to max. 1 second from turning ON/OFF of
SHUTTER IN (X8) to turning ON/OFF of SHUTTER CLOSE 1 OUT (Y8) and SHUTTER
CLOSE 2 OUT (Y9).
SHUTTER CLOSE 1 OUT and SHUTTER CLOSE 2 OUT will be output by the same
operation, but their output timing has a margin of error.
Turn on GUIDE IN (No.23) with the shutter closed.
After a lapse of 0.5ms or more from specifying SELECT 0 IN to SELECT 2 IN, turn on
GUIDE IN.
The guide laser is stopped automatically after passing 1 minute from start-up.
SELECT 0 IN (No. 19)
OFF
ON
OFF
ON
ME-LPRF-SM-11
*1
T3
T2
T1
SELECT 1 IN (No. 20)
OFF
OFF
ON
ON
*2
T4
SELECT 2 IN (No. 21)
OFF
OFF
OFF
OFF