Preparation Of Readout Code - Panasonic LP-RF Series Setup & Maintenance Manual

Laser marker
Hide thumbs Also See for LP-RF Series:
Table of Contents

Advertisement

„ Connectable code reader
This product can be connected with a code reader that can be operated in the RS-232C communication settings described
below.
„ Communication settings (for code reader linkage control)
Communication settings for use of the code reader linkage function are listed below.
Specify the code reader communication settings according to this setting.
Item
Synchro system
Communication type
Baud rate
Data length
Stop bits
Parity
Flow control
Start code
Check sum
End code
Reception timer
• This does not guarantee the communication with all code readers. Check the performance and operation before use.
• To connect the RS-232C port with the code reader, the communication command control by RS-232C is disabled.
• The control is enabled only when the laser marker is in the remote or run status.

6-2-4 Preparation of readout code

„ String that can be transferred
To use the code reader linkage function, check that the readout bar code/2D code data to read satisfy the following
conditions.
• Generate code data by alphanumeric characters and symbols within the range of ASCII code 20(HEX) to 7E(HEX).
• To set the file number, specify it always with 4-digits.
• Do not contain two-byte characters and/or control codes in the code data.
• When two-byte "%" is used, replace the code data with the following characters.
Characters you want to use
%
• As long as the code data to read satisfy the above conditions, any code type can be used.
• If any character that is not supported is contained in the read code, data cannot be transferred to the laser marker
regardless of data extraction setting.
• For the list of ASCII codes, refer to "Serial Communication Command Guide".
RS-232C communication specifications (for code reader linkage control)
Start-stop method
Full-duplex transmission
1200 / 2400 / 4800 / 9600 / 19200 / 38400 / 57600 / 115200 bps (initial setting: 9600 bps)
8-bit fixed
1-bit / 2-bit (initial setting: 1-bit)
None / Even / Odd (initial setting: None)
None
None (fixed)
None (fixed)
CR (Fixed)
Timeout monitoring ON (10 sec)
Characters to replace with
%%
ME-LPRF-SM-11
157

Advertisement

Table of Contents

Troubleshooting