  • Page 1 Handheld Thermography Camera HIKMICRO Pocket Series User Manual...
  • Page 2 MANUAL AND THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, ARE PROVIDED "AS IS" AND "WITH ALL FAULTS AND ERRORS". HIKMICRO MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK.
  • Page 3 Handheld Thermography Camera User Manual NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKMICRO HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS. YOU ACKNOWLEDGE THAT THE NATURE OF THE INTERNET PROVIDES FOR...
  • Page 4 Handheld Thermography Camera User Manual Regulatory Information FCC Information Please take attention that changes or modification not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC compliance: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
  • Page 5 Handheld Thermography Camera User Manual Note: Due to the device size limit, the above statement may not be disclaimed on the device. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. EU Conformity Statement This product and - if applicable - the supplied accessories too are marked with "CE"...
  • Page 6 Handheld Thermography Camera User Manual 5 G Wi-Fi (5.47 to 5.725 GHz) 23 dBm 5 G Wi-Fi (5.725 to 5.85 GHz) 14 dBm Directive 2012/19/EU (WEEE Directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points.
  • Page 7 Handheld Thermography Camera User Manual This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. ce matériel est conforme aux limites de dose d'exposition aux rayonnements, CNR-102 énoncée dans un autre environnement. (i) The device for operation in the band 5150-5250 MHz is only for indoor use to reduce the potential for harmful interference to co-channel mobile satellite systems;...
  • Page 8 Handheld Thermography Camera User Manual et 5650-5850 MHz et que ces radars pourraient causer du brouillage et/ou des dommages aux dispositifs LAN-EL. B 급 기기 : 이 기기는 가정용 (B 급 ) 전자파적합기기로써 주로 가정에서 사용하는 것을 목적으로 하며 , 모든 지역에서 사용할 수 있습니다 .
  • Page 9 Handheld Thermography Camera User Manual Symbol Conventions The symbols that may be found in this document are defined as follows. Symbol Description Indicates a hazardous situation which, if not Danger avoided, will or could result in death or serious injury. Indicates a potentially hazardous situation which, if Caution not avoided, could result in equipment damage,...
  • Page 10 Handheld Thermography Camera User Manual Safety Instruction These instructions are intended to ensure that user can use the product correctly to avoid danger or property loss. Laws and Regulations ● Use of the product must be in strict compliance with the local electrical safety regulations.
  • Page 11 Handheld Thermography Camera User Manual manufacturer. ● The built-in battery cannot be dismantled. Please contact the manufacture for repair if necessary. ● For long-term storage of the battery, make sure it is fully charged every half year to ensure the battery quality. Otherwise, damage may occur. ●...
  • Page 12 Handheld Thermography Camera User Manual ● Please notice that the current limit of USB 3.0 PowerShare port may vary with the PC brand, which is likely to result in incompatibility issue. Therefore, it’s advised to use regular USB 3.0 or USB 2.0 port if the USB device fails to be recognized by PC via USB 3.0 PowerShare port.
  • Page 13 ● The pollution degree is 2. Technical Support The https://www.hikmicrotech.com portal will help you as a HIKMICRO customer to get the most out of your HIKMICRO products. The portal gives you access to our support team, software and documentation, service contacts, etc.
  • Page 14: Table Of Contents

    Handheld Thermography Camera User Manual Contents Chapter 1 Overview ................1 1.1 Device Description ................ 1 Main Function ..................1 1.3 Appearance ................... 2 Chapter 2 Preparation ................5 2.1 Charge Device ................5 2.2 Power On/Off ................5 2.2.1 Set Auto Power-off Duration ..........5 2.3 Operation Method ................
  • Page 15 Handheld Thermography Camera User Manual Chapter 5 Picture and Video ............... 15 5.1 Capture Picture ................15 5.2 Record Video ................16 5.3 Manage Albums ................16 5.3.1 Create a New Album ............17 5.3.2 Rename an Album .............. 17 5.3.3 Change the Default Saving Album........
  • Page 16 Handheld Thermography Camera User Manual 11.2 Set Date and Time ..............29 11.3 Upgrade Device ................. 29 11.4 Restore Device................30 Chapter 12 Appendix ................31 12.1 Common Material Emissivity Reference ........31 12.2 Device Command ..............31 12.3 Device Communication Matrix ..........32 12.4 FAQ ....................
  • Page 17: Chapter 1 Overview

    Device supports multiple palettes, and you can set the palette mode according to the alarm function. Client Software Connection ● Mobile Phone: You can view live view, capture snapshots, and record videos via HIKMICRO Viewer App on your phone. You can also, analyze...
  • Page 18: Appearance

    Handheld Thermography Camera Pocket Series User Manual pictures offline, generate and share a report via the app. Scan the QR codes on the cover to download the App. HIKMICRO Viewer Android HIKMICRO Viewer iOS ● PC: You can download HIKMICRO Analyzer (https://www.hikmicrotech.com/en/product-c-detail/18) to analyze...
  • Page 19 Handheld Thermography Camera Pocket Series User Manual Figure 1-1 Appearance Table 1-1 Button and Interface Description Description Function Home Key Tap to return to the live view interface. File Key Tap to enter albums. Settings Key Tap to enter settings interface.
  • Page 20 Handheld Thermography Camera Pocket Series User Manual Description Function Tripod Mount Mount the tripod. Strap Attachment Mount the strap. Point Indicate the charging status of the device.  Solid red: charging normally Indicator  Flashing red: charging exception  Solid green: fully charged...
  • Page 21: Chapter 2 Preparation

    Handheld Thermography Camera Pocket Series User Manual Chapter 2 Preparation 2.1 Charge Device Before You Start Please make sure the battery is installed before charging. Steps 1. Lift the cover of cable interface. 2. Plug in the cable, and connect the power supply to charge the battery.
  • Page 22: Operation Method

    Handheld Thermography Camera Pocket Series User Manual 2.3 Operation Method The device supports both touch-screen control. You can tap the screen to set parameters and configurations. 2.4 Menu Description In the observation interface, tap the screen to show the menu bar, and swipe down to call the swipe-down menu.
  • Page 23: Chapter 3 Display Settings

    Handheld Thermography Camera Pocket Series User Manual Chapter 3 Display Settings 3.1 Set Screen Brightness You can drag the brightness adjustment bar in the swipe-down menu. Figure 3-1 Adjust Brightness via Swipe-Down Menu 3.2 Set Display Mode You can set the thermal/optical view of the device. Thermal, Fusion, PIP, and Optical are selectable.
  • Page 24: Set Palettes

    Handheld Thermography Camera Pocket Series User Manual Note When selecting the fusion mode, you need to set the parallax correction in the live view interface according to the distance to the target, so as to better overlap the thermal and optical images.
  • Page 25: Adjust Digital Zoom

    Handheld Thermography Camera Pocket Series User Manual 2. Tap the icons to select a palette type. White Hot The hot part is light-colored in view. Black Hot The hot part is black-colored in view. Rainbow The target displays multiple colors. It is suitable for scene without obvious temperature difference.
  • Page 26: Display Osd Info

    Handheld Thermography Camera Pocket Series User Manual Figure 3-3 Adjust Digital Zoom 2. Select the digital zoom value as required 3. Tap the screen to save and exit. 3.5 Display OSD Info Go to Local Settings → Device Settings → Display Settings to enable the information on-screen display.
  • Page 27: Chapter 4 Temperature Measurement

    Handheld Thermography Camera Pocket Series User Manual Chapter 4 Temperature Measurement The thermography (temperature measurement) function provides the real-time temperature of the scene and display it on the left of your screen. The thermography function is turned on by default.
  • Page 28: Set Unit

    Handheld Thermography Camera Pocket Series User Manual Set the relative humidity of current environment. 3. Return to previous menu to save the settings. Note You can go to Local Settings → Device Settings → Device Initialization → Measurement Tool Initialization to initialize the temperature measurement parameters.
  • Page 29: Set Thermography Rule

    Handheld Thermography Camera Pocket Series User Manual readjusts to the temperature range of the area. ● Adjust the maximum and minimum temperature of the range. ● Tap to select the max. temperature, min. temperature, or both. You can also tap the max.
  • Page 30 Handheld Thermography Camera Pocket Series User Manual alarm, and sending notification to the client software. Steps 1. Go to Local Settings → Thermography Settings → Alarm Settings → Temperature Alarm. 2. Enable the function and set the alarm threshold and alert threshold.
  • Page 31: Chapter 5 Picture And Video

    Handheld Thermography Camera Pocket Series User Manual Chapter 5 Picture and Video Insert memory card into the device, then you can record videos, capture snapshots, and mark and save important data. Note ● Device does not support capturing or recording when the menu is shown.
  • Page 32: Record Video

    Handheld Thermography Camera Pocket Series User Manual 6. Refer to Export Files to export the snapshots. 5.2 Record Video Before You Start Enable the flashlight via the swipe-down menu in dark environment. Steps 1. In the live view interface, hold the capture key to start recording. The recording icon and count down number display in the interface.
  • Page 33: Create A New Album

    Handheld Thermography Camera Pocket Series User Manual 5.3.1 Create a New Album Steps 1. Press to enter Albums. 2. Tap to add a new album. 3. A soft keyboard is displayed, where you can enter the name of the album by touching the screen.
  • Page 34: Delete An Album

    Handheld Thermography Camera Pocket Series User Manual 5.3.4 Delete an Album Steps 1. Press to enter Albums. 2. Select the album you want to delete. 3. Tap , and select Delete. A prompt box appears on the interface. 4. Tap OK to delete the album.
  • Page 35: Manage Files

    Handheld Thermography Camera Pocket Series User Manual 5.5 Manage Files You can move, delete, and edit the recorded files. Voice notes and messages can be added to the files. 5.5.1 Delete a File Steps 1. Press to enter Albums. 2. Tap to select the album storing the file to be deleted.
  • Page 36: Move A File

    Handheld Thermography Camera Pocket Series User Manual 5.5.3 Move a File Steps 1. Press to enter Albums. 2. Tap to select the album storing the file to be moved. 3. In the album, tap to select the file to be moved.
  • Page 37: Export Files

    Handheld Thermography Camera Pocket Series User Manual 6. Tap to finish. What to do next You can open the edited photo to view the text note. 5.6 Export Files Connect the device to your PC with supplied cable, you can export the recorded videos and captured snapshots.
  • Page 38: Chapter 6 Connect Bluetooth

    Handheld Thermography Camera Pocket Series User Manual Chapter 6 Connect Bluetooth You can record and hear the sound contained in the videos via bluetooth headsets after pairing the device with bluetooth headsets successfully. Steps 1. Select from the main menu.
  • Page 39: Chapter 7 Set Led Light

    Handheld Thermography Camera Pocket Series User Manual Chapter 7 Set LED Light Tap the flashlight button on the swipe-down menu to enable the LED light.
  • Page 40: Chapter 8 Cast Screen

    PC. Before You Start Download the UVC Alarm Client from HIKMICRO official website, and install the client on your PC. Refer to the user manual of the client for detailed operation.
  • Page 41: Chapter 9 Set Macro Mode

    Handheld Thermography Camera Pocket Series User Manual Chapter 9 Set Macro Mode In the macro mode, you can focus extremely close on a very small object, and the object appears much larger in the view (and in the final image) compared to the standard lens.
  • Page 42: Chapter 10 Thermal View App Connection

    Handheld Thermography Camera Pocket Series User Manual Chapter 10 Thermal View APP Connection The device supports both Wi-Fi connection and hotspot. Connect the device to HIKMICRO Viewer, and you can control the device via mobile client. 10.1 Connect via Wi-Fi Before You Start Download and install HIKMICRO Viewer on your phone.
  • Page 43: Connect Via Hotspot

    Handheld Thermography Camera Pocket Series User Manual 7. Launch the App and follow the startup wizard to create, and register an account. 8. Add the device to online devices. Result You can view the live view, capture snapshots, and record videos via the App.
  • Page 44 Handheld Thermography Camera Pocket Series User Manual ● The password should contain at least 8 digits, consisting of numbers and characters. 5. Tap to save. 6. Connect your phone to the hotspot of the device. 7. Launch the App and follow the startup wizard to create, and register an account.
  • Page 45: Chapter 11 Maintenance

    Handheld Thermography Camera Pocket Series User Manual Chapter 11 Maintenance 11.1 View Device Information Go to Local Settings → Device Information to view the device information. 11.2 Set Date and Time Steps 1. Go to Local Settings → Device Settings → Time and Date.
  • Page 46: Restore Device

    Handheld Thermography Camera Pocket Series User Manual Note After upgrading, the device reboots automatically. You can view the current version in Local Settings → Device Settings →Device Information. 11.4 Restore Device Go to Local Settings → Device Settings → Device Initialization to initialize...
  • Page 47: Chapter 12 Appendix

    Handheld Thermography Camera Pocket Series User Manual Chapter 12 Appendix 12.1 Common Material Emissivity Reference Material Emissivity Human Skin 0.98 Printed Circuit Board 0.91 Concrete 0.95 Ceramic 0.92 Rubber 0.95 Paint 0.93 Wood 0.85 Pitch 0.96 Brick 0.95 Sand 0.90 Soil 0.92...
  • Page 48: Device Communication Matrix

    HIKMICRO thermal cameras. 12.3 Device Communication Matrix Scan the following QR code to get device communication matrix. Note that the matrix contains all communication ports of HIKMICRO thermal cameras. 12.4 FAQ Scan the following QR code to get device common FAQ.
  • Page 49 Facebook: HIKMICRO Thermography LinkedIn: HIKMICRO Instagram: hikmicro_thermography YouTube: HIKMICRO Thermography E-mail: info@hikmicrotech.com Website: https://www.hikmicrotech.com/ UD29202B...