Page 1
Handheld Thermography Camera HIKMICRO B Series User Manual Contact Us...
Page 2
DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKMICRO HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS. YOU ACKNOWLEDGE THAT THE NATURE OF THE...
Page 3
Regulatory Information These clauses apply only to the products bearing the corresponding mark or information. FCC Compliance Statement Note: This product has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Page 4
Refer to the product specification for detailed battery requirements For the device without a supplied power adapter, use the power adapter provided by a qualified manufacturer. Refer to the product specification for detailed power requirements. Directive 2012/19/EU (WEEE Directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union.
Page 5
(2) cet appareil doit accepter toute interférence reçue, notamment les interférences susceptibles d’occasionner un fonctionnement indésirable de l’appareil. Cet appareil est conforme aux limites d’exposition au rayonnement IC RSS-102 établies pour un environnement non contrôlé. Safety Instruction The symbols that may be found in this document are defined as follows.
Page 6
Technical support https://www.hikmicrotech.com/en/contact-us.html portal will help you as a HIKMICRO customer to get the most out of your HIKMICRO products. The portal gives you access to our support team, software and documentation, service contacts, etc. Using Environment ●...
Page 7
warranty. Keep the device power off when replacing laser assembly. Caution-Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. Manufacture Address: Room 313, Unit B, Building 2, 399 Danfeng Road, Xixing Subdistrict, Binjiang District, Hangzhou, Zhejiang 310052, China Hangzhou Microimage Software Co., Ltd.
Client Software Connection Mobile Phone: You can view live view, capture snapshots, record videos via HIKMICRO Viewer app on your phone. You can also analyze radiometric images, generate and share a report via the app. Scan the QR codes to download the app.
2 Appearance Screen Back Charging Indicator Buzzer On/OK/Menu Navigation Function Button Hold: Power on/off Press: Display menu or confirm operation. Exit the menu or return to previous menu. In menu mode: Press to select parameters. In live view mode: Press to switch image mode (only supported by certain models), and press...
Page 11
Thermal Lens Laser Lens Protector Switch Trigger Component Function Charging Solid Red: Charging. Indicator Solid Green: Fully charged. Type-C Charge the battery or export Interface snapshots. In live view: Press: Capture snapshots. Hold: Locate the target with laser light, and release to capture Trigger snapshots (only supported...
3 Preparation Charge Device Steps: Open the top cover of the camera. Connect the device interface and the power adapter with Type-C cable. Type-C Power On/Off Power On Remove the lens cover, and hold for over three seconds to turn on the device. You can observe the target when the interface of the device is stable.
Unit Hotspot Battery Status Real-time Temperature Min. Temperature Display Center Temperature Display Color- Max. Temperature Temperature Scale Display Emissivity Distance 4 Display Settings Set Image Mode You can set image modes of the device. Image Mode is only supported by certain models. Please refer to the actual device or the datasheet.
Your camera will periodically perform a self- calibration to optimize image quality and measurement accuracy. In this process the image will pause briefly and you will hear a “click” as a shutter moves in front of the detector. The self-calibration will be more frequent during the startup or in very cold or hot environments.
Set Color Distribution Set the color distribution to change the distribution of colors in the image. Different color distributions facilitate you to better analyze the image. Steps: In the live view interface, press go to More Settings → Color Distribution. Select a color distribution mode.
left top of your screen. The function is enabled by default. Set Measurement Parameters You can set temperature measurement parameters to improve the accuracy of temperature measurement. Steps: In the live view interface, press show the menu. Press to select desired parameters.
The device shows the real-time temperature on the upper left side of live view interface. Enhance High-Temperature Target In target enhancement function, when the target’s temperature is higher than the set value, the target will become red. Steps: In the live view interface, press select Palettes.
threshold value, the device will output alarm. Press to save and exit. 6 Capture Snapshots Capture One Image You can capture snapshots in live view, and a thumbnail of the snapshot is displayed in live view. The snapshot will be automatically saved in the albums.
Purpose: Connect the device to your PC with Type-C cable, and then you can export the captured snapshots. You can also export snapshots via HIKMICRO Viewer. See HIKMICRO Viewer Connection. Steps: Open the interface cover. Connect the camera to your PC with Type-C cable and open the detected disk.
9 HIKMICRO Viewer Connection The device supports both Wi-Fi connection and WLAN hotspot. Connect the device to HIKMICRO Viewer app, and you can control the device via mobile app. This function is only supported by certain models. Please refer to the actual product for reference.
Turn on the device hotspot and complete hotspot settings. See Set Device Hotspot for instructions. You can connect the device hotspot by the following ways. − Connect your phone to the device hotspot and enter the hotspot password. − Launch the app and scan the hotspot QR code of the device with the app.
● After disabling this function, the parameters will be restored to the previous set values, and the temperature range will be set to auto switch. 11 Cast Screen The device supports casting screen to PC by UVC protocol-based client software or player. You can connect the device to your PC via a type-C cable, and cast the real-time live view of the device to your PC.
13.4 Format Storage Steps: In the live view interface, press go to More Settings → Format Storage. Press and select OK to start formatting storage. Note Format storage before first use of it. 13.5 Upgrade Before You Start ● Download the upgrade package from the official website first.