1 Scope of Manual
The following user information covers the MaxFlo 4 general
service control valve:
• DIN Units – PN 10-63, DN 25-300
• ASME Units – Class 150 – 600, NPS 1 – 12
• Assembled with a pneumatic actuator
• Comes with or without ancillary equipment
2 Intended Use
Control valves are pressure ves
WARNING
sels designed and rated for spe
cific application conditions. Before installation, check the
serial number and / or the tag number to ensure that the
valve and actuator being installed are correct for the in
tended application. Do not use the valve outside of its rated
design limits. Exceeding the design limits may cause haz
ardous conditions including leakage of the process media
or rupture of the pressure boundary resulting in possible
process loss, equipment or environmental damage, or seri
ous personal injury or death.
The specific product design data can be found on the valve's
serial plate, data sheet and the calculation sheet (in acc. to the
IEC 60534-7:2010).
The MaxFlo 4 handles a wide variety of appli cations, while
offering high flow capacity. Restricted trim and noise reduction
plates available as an option.
The MaxFlo 4 consists of the body, bonnet, trim, transfer case
and actuator. The valve is designed with a high level of
in terchangeability allowing the user to assemble the greatest
possible number of variations from a minimum number of
components to match each application.
The MaxFlo 4 is designed for use in ambient temperature range
-40°F to 158°F (-40°C to 70°C), air humidity up to 93% non-
condensing, air pollution up to 300 µg/m
by the accessories.
The product offering may include optional ancillary equip-
ment, such as positioners, air-filter regulators, solenoid
valves, limit switches or boosters. Digital, I/P , or pneumatic
positioners can be mounted directly, with a mounting bracket
or according to NAMUR standards. Refer to the relevant man-
ufacturer's user instructions for information regarding other
ancillary equipment.
3 Product Identification
Each MaxFlo 4 control valve comes with an attached serial
plate which includes key information specifically for each con-
trol valve:
The same serial number shown on the plate will appear on all
MaxFlo 4 data sheets, dimensional drawings, bills of material,
and spare parts lists. Other information located on the serial
plate is self-explanatory for the MaxFlo 4 control valve.
You can download .pdf versions of the MaxFlo 4 documenta-
tion including a sales brochure, technical bulletin and user
instructions at www.flowserve.com. It is the user's respon-
sibility to keep this and related documentation on file and ac-
cessible for the MaxFlo 4 product.
4 MaxFlo 4 Modification
MaxFlo 4 control valves are generally delivered as tested and
assembled units, with factory-mounted actuators.
Unauthorized modification of the MaxFlo 4 con
, unless restricted
3
trol valve voids the product test certification and
product warranties, could drastically affect prod
uct performance, and could be hazardous to per
sonnel and equipment.
NOTICE
pliance with all test routines, guidelines and engineering
standards.
MaxFlo 4 Control Valve FCD VLENIM0064-02-AQ – 09/16
Figure 2: Valve Serial Plate
Figure 3: NR Actuator Serial Plate
Before MaxFlo 4 re-use, all necessary tests
must be repeated and recorded in com-
3
flowserve.com