Flowserve Series 081000 User Instructions

Flowserve Series 081000 User Instructions

Low and micro flow valves

Advertisement

User Instructions SmallFlow 080/081000 - KMENIM8000-01 08/11
®
USER INSTRUCTIONS
Kämmer
SmallFlow
®
080000 / 081000
- Series
Low and Micro Flow Valves
Operation
FCD KMENIM8001-01 08/11
Experience In Motion
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Series 081000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Flowserve Series 081000

  • Page 1 User Instructions SmallFlow 080/081000 - KMENIM8000-01 08/11 ® USER INSTRUCTIONS Kämmer SmallFlow ® ™ 080000 / 081000 - Series Installation Low and Micro Flow Valves Operation FCD KMENIM8001-01 08/11 Maintenance Experience In Motion...
  • Page 2 Between actuator and Compliance with other, not particularly emphasised valve there are moving parts. To avoid injury Flowserve notes, with regard to transport, assembly, operation provides pinch-point-protection in the form of cover and maintenance and with regard to technical plates, especially where side-mounted positioners documentation (e.g.
  • Page 3 If the valve is to be welded into the line, make sure of missing product-related information, clarification that the valve is shielded from excessive heat. must be obtained via the appropriate FLOWSERVE sales office. Connect supply pressure and signal lines. Control valves are usually supplied with a positioner.
  • Page 4 User Instructions SmallFlow 080/081000 - KMENIM8000-01 08/11 ® Check all air connections for leaks. note: With graphite packing, irregular movement of the plug stem is normal. Tighten packing nut (see table 1 ) Warning: Keep hands, hair, clothing, etc. away from STOP! all moving parts.
  • Page 5 User Instructions SmallFlow 080/081000 - KMENIM8000-01 08/11 ® Actuator stem Actuator stem Coupling Coupling screw Coupling screw Coupling Coupling insert Coupling insert Locknut Locknut Yoke plate Yoke plate Yoke plate nut Yoke plate nut actuator series 2, type P1 actuator series 2, types P2, P3, P4 Fig.
  • Page 6 User Instructions SmallFlow 080/081000 - KMENIM8000-01 08/11 ® Locknut Gland nut Packing follower Clamp nut Packing Guide bushing Bonnet Gasket Plug stem Seat ring Anti-rotation plate with retaining screw Body typical valve configuration Fig. 3 6.2.1 Screw coupling insert locknut and coupling insert as 6.2.5 coupling for actuator series 4 far as possible onto plug stem.
  • Page 7 User Instructions SmallFlow 080/081000 - KMENIM8000-01 08/11 ® 7.2.4 Replace the gasket. loosen and unscrew the bonnet assembly from the valve. 7.2.5 Insert the plug into the bonnet. Install the guide bush- ing into the packing chamber with bevelled end facing 7.1.4 Carefully remove the plug from the bonnet.
  • Page 8 Fax: +1 412 787 1944 singapore Flowserve Pte ltd 12 Tuas Avenue 20 Singapore, 638824 Singapore Tel.: +65 6879 8989 Fax: +65 6862 4940 Contact: All data subject to change without notice © 08.2003 Flowserve Corporation. Flowserve and Kämmer are trademarks of Flowserve Corporation...

This manual is also suitable for: