Protective devices like Fuses and Circuit Breakers are included to protect against short-circuits
and/or overload currents. The general idea of the fuse is that it melts a conductive link when
current gets higher than its rating and thus stops the current flowing.
OFF
ON
SYSTEM MASTER
PUMP BOX
CAUTION: Each Red Fuse is rated for 10 Amps; do not replace it for one of higher rating. Each
Circuit Breaker is rated for 25 Amps. Do not replace it for one of higher rating.
PUMP BOX
10 AMP FUSE
SYSTEM MASTER
VOLT/HOUR METER
ACTUATOR
RELAYS
FUSE
PUMP
P/N 65303
25 AMP CIRCUIT BREAKER
BLOWER/FAN
If a fuse blows, or if the circuit breaker opens the circuit, it means that a short-circuit and/or
overload situation was present, and a detailed inspection is required to define the condition or
fault which caused the protective device to activate.
ON
PUMP CALIBRATE
DETAIL "A"
10 AMP FUSE
FOR CALIBRATE
FUNCTION
PUMP
FUSE BLOCK
The Circuit Breaker is a thermal device used in
the motor distribution system for protecting
against overload and short-circuits in the system.
The circuit breaker has a "switch" on it which
opens once the current exceeds its rating. It has a
time delay effect with brief over-current conditions
(common in motor start up).
Automatic reset circuit breakers will recycle
continuously during an over-current condition.
The composite alloy material will deflect and
separate the contacts when an over-current
situation occurs and return to the run mode as it
cools. The process will continue until the source
of the over-current is removed or corrected.
DETAIL "A"
(3) 25 AMP CIRCUIT
BREAKER ATOMIZER
MOTOR CONTROL
CIRCUIT BREAKER
P/N 65286