Preventative Maintenance Schedule - Curtis DYNA-FOG DYNA-JET L30 2 Series Installation, Operation And Maintenance Manual

Dc rotary atomizer, electric ulv sprayer
Table of Contents

Advertisement

Preventative Maintenance Schedule

Dyna-Jet L30
Maintenance
Check Sprayer
Time Interval
Voltage
Battery meter on
Daily
remote box
should show at
least 11 Volts.
Weekly
Monthly
Flush
Wash
formulation
Machine
system
Flush for 2-
Wash using mild
3 minutes
detergent being
after each
careful not to spray
use
water directly on
motor and other
electrical
connections. Do not
use high pressure
spray to clean the
machine!
Check machine
Clean the
mounting
formulation
filter
Verify that all
Remove the
mounting bolts
filter bowl
are tight and
and clean
that the
the
machine is held
formulation
securely in
filter
position.
(located on
the pickup
tube of the
formulation
tank)
Inspect Atomizer
Inspect electrical
and Motor
connections
Ensure atomizer
Ensure all electrical
retaining nut and
connection are
motor mounting
tight. Check
battery liquid level
screws are tight
and add water if
needed. See
battery
manufacturer's
recommendations.
19

Advertisement