Pump Calibration- (For the Dyna-Jet Model L30 without the Syncroflow System)
Before attempting to spray, the FMI pump must be calibrated to the proper flow rate setting. The
required flow rate is dictated by the information on the formulation manufacturer's label. Calibration
is performed using the "Calibration Switch" located inside the pump enclosure, not from the
Remote Control Box.
Using the Calibration Switch does not require having the Atomizer and Blower operating.
Once the switch is depressed liquid will be pumped into the atomizer!
safety goggles and respirator when handling any type of formulations. Take
precautions to avoid spills and do not allow the formulation to contact your skin.
In the event of an accident know the proper measures to take. Always follow the information
Calibration Steps:
1) Loosen the two locking knobs and position the indicator to the setting in the Flow Table below that
is closest to your desired output. Note: Tighten both locking knobs after adjusting the pump.
Leaving the locking knobs loose can allow the cylinder to move and damage the pump.
2) Remove the atomizer dust cover and disconnect the formulation delivery tube at the rear of the
atomizer. Connect the calibration tube to the formulation tube and place the end of the tube in a
beaker or graduated cylinder.
3) Add insecticide (or other formulation to be sprayed) to the Formulation Tank.
4) Turn ON the Master ON/OFF switch located inside the pump enclosure.
Always wear OSHA approved protective clothing, gloves,
contained on the formulation manufacturer's label.

Flow Rate Table

DYNA-JET L30 (FMI Pump)
Flow oz/min (ml/min)
5.0 (148)
9.0 (266)
12.5 (370)
14.0 (414)
CAUTION:
WARNING
Pump Setting
2
4
6
7 (Max)
FMI Pump
Locking Knob
14