Flushing

To keep your machine operating efficiently, you must always flush the machine after every spray
application. Flushing helps to remove contaminates and residuals left in the formulation pump, tubes
and atomizer sleeve from the formulation. These residuals can sometimes be thick and have a look
of "varnish". When the spray operation is complete, place the Formulation/Flush Switch to the Flush
position and turn the spray on. You should always perform the first minute of flushing while the
vehicle is moving until all insecticide is purged from the system. Once the insecticide is purged, it is
safe to complete the flushing operation with the vehicle stopped. Flush for 2-3 minutes. Use only
®
Dyna-Fog flushing solution, or a Curtis Dyna-Fog approved flushing agent such as Aire-Mate
ULV
Flushing Solution (Specify Part No. 1-0224).
Click on the following hyperlink to go to
www.airemate.com
and specify P/N-1-0224.