Page 1
All information contained in these materials, including products and product specifications, represents information on the product at the time of publication and is subject to change by Renesas Electronics Corp. without notice. Please review the latest information published by Renesas Electronics Corp.
Page 2
Renesas Electronics disclaims any and all liability for any damages or losses incurred by you or any third parties arising from the use of any Renesas Electronics product that is inconsistent with any Renesas Electronics data sheet, user’s manual or other Renesas Electronics document.
Page 3
Unit Products The following usage notes are applicable to all Microprocessing unit and Microcontroller unit products from Renesas. For detailed usage notes on the products covered by this document, refer to the relevant sections of the document as well as any technical updates that have been issued for the products.
Page 4
Renesas or its affiliates shall in no event be liable for any loss of profit, loss of data, loss of contract, loss of business, damage to reputation or goodwill, any...
Figure 1. RSK-RX65N-2MB Setup with RYZ014A_PMOD Board Connected ..........7 Figure 2. Creating a New Project on Renesas Flash Programmer ..............8 Figure 3. The Main Window of Renesas Flash Programmer After Creating a New Project ......9 Figure 4. Connections for the RX65N-2MB Board After Flashing ..............10 Figure 5.
Page 6
Cellular IoT Modules RYZ014A Pmod with RSK-RX65N-2MB – Quick Start Guide Figure 11. Validating SIM Activation ......................13 Figure 12. Creating a Device Profile on Launchpad ..................14 Figure 13. Registering RSK-RX65N-2MB on Launchpad ................14 Figure 14. Activating the SIM card on Launchpad ..................15 R20QS0041EG0100 Rev.1.00...
• Instructions for running the RYZ014A_PMOD example project on the RSK-RX65N-2MB board. • Instructions for flashing the RYZ014A_PMOD example project code using Renesas Flash Programmer. 1.1 Assumptions and Advisory Notes 1. Tool experience: It is assumed that the user has prior experience working terminal emulation programs such as TeraTerm.
Mini-B end of the second USB device cable to the E2 Lite Debugger and the Type-A end to the host 3. Connect the power cable from the AC adapter to the power jack on the RSK-RX65N-2MB board (PWR). 4. Open Renesas Flash Programmer and create a new project by using the File menu and selecting New Project.
Cellular IoT Modules RYZ014A Pmod with RSK-RX65N-2MB – Quick Start Guide Figure 3. The Main Window of Renesas Flash Programmer After Creating a New Project 8. Click Start to begin flashing the example project code onto the board. Once completed, the message Operation Complete should be printed and the status OK should be displayed next to the start button.
Cellular IoT Modules RYZ014A Pmod with RSK-RX65N-2MB – Quick Start Guide 5.2 Connecting and Powering Up the RSK-RX65N-2MB Board 1. Connect the RYZ014A_PMOD board to PMOD1 connector labeled on the board. 2. Connect the Mini-B connector end of the USB device cable to the USB Mini-B port (G1CUSB0) of the RSK-RX65N-2MB board.
Cellular IoT Modules RYZ014A Pmod with RSK-RX65N-2MB – Quick Start Guide 5.3 Running the RYZ014A_PMOD Example Project To run the RYZ014A_PMOD example project, use the following instructions: 1. On the host PC, open Windows Device Manager. Expand Ports (COM & LPT), locate USB Serial Device (COMxx) and note down the COM port number for reference in the next step.
Cellular IoT Modules RYZ014A Pmod with RSK-RX65N-2MB – Quick Start Guide 3. Using the Setup menu pull-down, select Serial port… and ensure that the speed is set to 115200, as shown below. Figure 7. Selecting 115200 on the Speed Pulldown 4.
1. Create a Launchpad account by registering on the sign-up page and verifying the account through the verification email sent after registration. 2. Login to the new Launchpad account and click on the Create Device Profile tile. Make sure Renesas RSK-RX65N is selected for the Device Type and CAT-M (RYZ014A-PMOD) for the Connectivity Type.
Cellular IoT Modules RYZ014A Pmod with RSK-RX65N-2MB – Quick Start Guide Figure 12. Creating a Device Profile on Launchpad 3. On Data Schema, click Next. 4. On Select a Plan, apply any valid promo codes if applicable and click Next.
Cellular IoT Modules RYZ014A Pmod with RSK-RX65N-2MB – Quick Start Guide 7. Click Next and click Add New SIM. Enter the ICCID value for the SIM EID field and click Save SIM. Figure 14. Activating the SIM card on Launchpad 8.
Cellular IoT Modules RYZ014A Pmod with RSK-RX65N-2MB – Quick Start Guide 7.3 SIM Card Activation problem • If the SIM activation fails, verify that the IMEI and ICCID numbers are correctly entered when registering the device on Launchpad • SIM cards cannot be activated more than once. If a SIM card has been activated, the SIM card activation will fail when trying to add a new SIM (see Figure 14).