Raid Scanning - Buffalo LinkStation 420DS User Manual

Table of Contents

Advertisement

5
Check "Add a disk to RAID array with RMM. Your data will be preserved.".
6
Select the drive whose data will be saved from the drop-down menu.
7
Select the drive to add to the RAID array.
8
Click Create RAID Array.
9
The "Confirm Operation" screen will open. Enter the confirmation number, then click OK.

RAID Scanning

A RAID scan checks your RAID array for bad sectors and if it finds any it automatically repairs them. RAID 1 arrays are
supported. For best result, run RAID scans regularly.
1
In Advanced Settings, click Drives.
2
Move the RAID scanning switch to the
3
Click
to the right of "RAID Scanning".
4
Click Edit.
5
Select the schedule for running RAID maintenance, then click OK.
Notes:
• Check "Immediately" to run a RAID scan immediately.
• To stop a RAID scan, click Cancel RAID Scan.
• Even if the RAID scan finishes, the I17 message may appear in NAS Navigator2 and the power LED may blink
amber. To remove the I17 message from NAS Navigator2 and stop the power LED from blinking, restart your
LinkStation.
position to enable RAID scanning.
27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ls420ds

Table of Contents