Maximum Number Of Starts Per Hour; Sound Pressure - Xylem e-IXP Installation, Operation And Maintenance Instructions

Table of Contents

Advertisement

8.5 Maximum number of starts per hour

Power, kW
0.75 – 3
4 – 7.5
11 – 22
30 – 37
45 – 75
90 – 160
200
355 - 500
Note: The above table is by way of example and not exhaustive. Always refer to the motor
manual.

8.6 Sound pressure

Measured in free field at a distance of one metre from the unit, operating without load.
LpA, dB ± 3
Power, kW
0.75, 1.1, 1.5, 2.2, 3, 4, 5.5, 7.5, 11, 15
18.5
22
30
37
45
55
75
90
110
132
160
200
250
315
355
400
450
500
e-IXP, e-IXPC, e-IXPF – Installation, Operation and Maintenance Instructions
Starts / h
60
40
25
16
8
4
3
2
-1
Pump @ min
2950
1450
950
< 70
< 70
< 70
< 70
< 70
< 70
< 70
< 70
< 70
< 70
< 70
< 70
70.5
< 70
< 70
71.5
70.5
70.0
72.4
71.4
70.9
73.8
72.9
72.4
74.8
73.8
73.3
75.7
74.7
74.2
76.5
75.6
75.0
77.4
76.5
75.9
78.5
77.6
77.0
79.5
78.6
78.0
-
79.7
79.1
-
80.2
79.7
-
80.9
80.3
-
81.4
80.9
-
81.9
81.3
en – Original instructions
Pump with standard motor, @ min
2950
1450
950
< 70
< 70
< 70
70.1
< 70
< 70
70.6
< 70
< 70
71.8
< 70
< 70
73.8
73.4
70.1
74.8
71.6
71.2
76.9
72.7
71.9
78.7
74.1
73.5
79.7
74.8
74.2
80.0
76.6
75.0
80.9
77.2
75.6
81.3
77.6
76.6
82.3
78.9
78.5
82.8
79.7
79.2
-
80.7
-
-
81.1
-
-
-
-
-
-
-
-
-
-
-1
43