Toshiba G7 Operation Manual page 135

Adjustable speed drive
Hide thumbs Also See for G7:
Table of Contents

Advertisement

F444
Driving Torque Limit #2
Program ⇒ Torque Setting Parameters ⇒ Manual Torque Limit
Settings
This parameter is used to set the positive torque upper limit for the #2 motor
profile when multiple motors are controlled by a single drive or when a single
motor is to be controlled by multiple profiles.
Regeneration Torque Limit #2
Program ⇒ Torque Setting Parameters ⇒ Manual Torque Limit
Settings
This parameter is used to set the negative torque upper limit for the #2 motor
profile when multiple motors are controlled by a single drive or when a single
motor is to be controlled by multiple profiles.
Driving Torque Limit #3
Program ⇒ Torque Setting Parameters ⇒ Manual Torque Limit
Settings
This parameter is used to set the positive torque upper limit for the #3 motor
profile when multiple motors are controlled by a single drive or when a single
motor is to be controlled by multiple profiles.
Regeneration Torque Limit #3
Program ⇒ Torque Setting Parameters ⇒ Manual Torque Limit
Settings
This parameter is used to set the negative torque upper limit for the #3 motor
profile when multiple motors are controlled by a single drive or when a single
motor is to be controlled by multiple profiles.
G7 ASD Operation Manual
Direct Access Number — F444
Parameter Type — Numerical
Factory Default — 250.0
Changeable During Run — Yes
Minimum — 0.0
Maximum — 250.0
Units — %
Direct Access Number — F445
Parameter Type — Numerical
Factory Default — 250.0
Changeable During Run — Yes
Minimum — 0.0
Maximum — 250.0
Units — %
Direct Access Number — F446
Parameter Type — Numerical
Factory Default — 250.0
Changeable During Run — Yes
Minimum — 0.0
Maximum — 250.0
Units — %
Direct Access Number — F447
Parameter Type — Numerical
Factory Default — 250.0
Changeable During Run — Yes
Minimum — 0.0
Maximum — 250.0
Units — %
F447
127