24 vac universal intermittent pilot gas ignition contro

Advertisement

Table 2 DIP Switch (S1) Settings
Timing Configurations
SEL
# of
Pre-
Trials
Purge
#
sec
0
1
1
1
30
2
1
3
1
30
4
1
5
1
30
6
1
7
1
30
8
3
9
3
30
10
3
11
3
12
3
45
13
3
14
Cont.
15
Cont.
30
16*
1
17*
1
18*
1
19*
1
20*
1
21*
1
15
22*
1
23*
1
24*
1
25*
1
26*
1
27*
1
28*
9
29*
9
15
30*
9
30
31*
-
* Approved CE timing configurations.
NOTE: Configurations with a number of trials are 100% lockout after the trials are
complete. All controls have a Quick Start and Re-ignition.
©
2018 BASO Gas Products
Part No. BASO-INS-C610UQRG, Rev. C
Inter-
TFI
Purge
sec
sec
0
4
0
4
0
0
15
0
15
0
0
30
0
30
0
0
90
0
90
0
0
60
15
60
15
0
90
15
0
60
300
60
300
0
90
360
0
90
15
90
15
0
4
0
4
8
0
0
15
0
0
30
0
4
30
0
30
0
0
50
0
4
50
0
0
90
0
0
120
0
4
120
0
0
240
0
0
90
15
90
15
90
15
-
-
-
24 VAC Universal Intermittent Pilot Gas Ignition Control
DIP (S1) Switch Settings
Retry
SW
SW
Time
min
1
2
5
OFF
OFF
5
OFF
OFF
5
OFF
OFF
5
OFF
OFF
5
OFF
OFF
5
OFF
OFF
5
OFF
OFF
5
OFF
OFF
5
OFF
ON
5
OFF
ON
5
OFF
ON
60
OFF
ON
60
OFF
ON
60
OFF
ON
N/A
OFF
ON
N/A
OFF
ON
0
ON
OFF
0
ON
OFF
0
ON
OFF
0
ON
OFF
0
ON
OFF
0
ON
OFF
0
ON
OFF
0
ON
OFF
0
ON
ON
0
ON
ON
0
ON
ON
0
ON
ON
0
ON
ON
0
ON
ON
0
ON
ON
-
ON
ON
SW
SW
SW
3
4
5
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
www.baso.com
5

Advertisement

loading