24 vac universal intermittent pilot gas ignition contro

Advertisement

WIRING
Table 1: Typical Wiring Connections.
Label
Term. Type
FC
- +
BRN
Mounting Tab
GND
(Lower left)
24V GND
1/4" male QC
BRN GND
MV
1/4" male QC
MV/PV
1/4" male QC
COM
PV
1/4" male QC
ALM
24V
1/4" male QC
TH-W
1/4 : male QC
RO
DAMPER
P1
keyed plug
DIP
5 position
SWITCH
DIP switch
S1
SENSE
1/4" male QC
INT
1/4" male QC
SPARK
1/4" male QC
* If the existing system uses a burner ground wire, this can be attached to the 24V
GND/BRN GND terminal using the supplied dual spade connector, or otherwise
connected to the burner ground mounting tab.
©
2018 BASO Gas Products
Part No. BASO-INS-C610UQRG, Rev. C
Description
2 pin
Flame Current test pins for measuring microamps in
µAmp DC with a microammeter
Burner Ground connection*
Common side (return) of transformer connection
Main Valve connection
Gas Valve common terminal
Pilot Valve connection
N/A
Alarm Output connection
24V Power for Vent Damper
Thermostat (CTH) connection
N/A
Rollout Switch connection
6-pin
Vent Damper connection. Leave Vent Damper
Jumper Plug installed if not a Vent Damper system
32 selectable timings of the most popular settings
Flame Sensor connection
- For dual rod (remote/external) flame sensing,
remove Jumper Wire installed and connect flame
sense wire from the burner/igniter to this terminal
- For single rod (local/internal) sensing leave
Jumper Wire connected to the INT connector
- For single rod (local/internal) sensing a Jumper
Wire is connected to the SENSE connector
NOTE: Remove and discard Jumper Wire for two
rod (remote/external) flame sensing
High voltage sparking electrode
24 VAC Universal Intermittent Pilot Gas Ignition Control
3
www.baso.com