Page 1
PARKER SEA RECOVERY ULTRO CLEAR Direct Feed (DF) LOW PRESSURE REVERSE OSMOSIS (RO) 400-1500 GPD SECOND PASS RO SYSTEM, DIRECT FEED (1.5 M3/day to 5.75 M3/day) QUICK START GUIDE UC-DF C o n f i d e n t i a l P a r k e r S e a R e c o v e r y...
Secure the RO system down with appropriate anchorage and vibration mounts, as necessary. Step 3A: Connect ½” tubing (Parker Nylon N series tubing) to the INLET port on the connection panel. Feed water is supplied directly from an upstream RO watermaker. Typical supply pressure is 20 to 50 psi.
Note: The recycle valve can be throttled slightly for fine tuning, as necessary, but never CLOSED RECYCLE VALVE BV35 FULLY OPEN, DEFAULT POSITION UC-DF Step 9A: Check the system to ensure all fittings and connections are tight and ready for operation. INITIAL STARTUP AND OPERATION...
Page 4
Nominal Product/Permeate flow ratings for each ULTROclear DF model are noted below. ZK-A1F One vessel rated flow 400 gpd / 17 gph max ZK-A2F Two vessel rated flow 800 gpd / 33 gph max ZK-A3F Three vessel rated flow 1,200 gpd / 50 gph max ZK-A4F Four vessel rated flow 1,500 gpd / 62 gph max...
J. RO feed 3-way inlet valve for two feed water sources (a) direct watermaker feed and (b) feed from dock-side potable water or the boats potable distribution system. Contact Parker engineering. General Service Guidelines C o n f i d e n t i a l P a r k e r S e a R e c o v e r y...
Page 7
1-4 years relating to source water turbidity/quality Note: System warranty requires the use of only Parker Hannifin/Water Purification spares, consumables, chemicals, components and appurtenances. Use of any other products or equipment voids all warranty for the system. Daily operational information for all pressure, flow, and conductivity in the system is required to be provided in the case of any warranty claims.
Page 8
5 – 10 minutes of steady-state operation. Note: For extended RO system shutdowns for more than 2-4 days, perform a cleaning and then flush a Parker preservative solution through the membranes. Parker Membrane Preservative: 85-0103 Standard RO Cleaning Guidelines - Fundamentals...
Page 9
ULTROclear DF Reverse Osmosis Overall Configuration Corrosion resistant durable low pressure RO system designed for use in marine environments PRIMARY ELECTRICAL CONNECTION RO VESSELS WITH 110V or 220V, 1PH MEMBRANE ELEMENTS TWO PREFILTER ON/OFF SELECTOR HOUSINGS AND SWITCH FILTER ELEMENTS C o n f i d e n t i a l P a r k e r S e a R e c o v e r y 0 6 1 2 2 0 1 7...
Page 10
Parker Water Purification – Sea Recovery Contact Information C o n f i d e n t i a l P a r k e r S e a R e c o v e r y 0 6 1 2 2 0 1 7...
Page 11
Parker ULTROclear Z Series RO Parameter Other Description mo./day/yr Date Source water Temperature conductivity Source water EC PI-10 Source water feed pressure PI-20 Filter out pressure PI-25 Membrane pressure PI-35 Concentrate pressure PI-50 Permeate pressure FI-50 RO permeate flow FI-40...
Page 12
Unit capacities from 400 GPD to 1500 GPD (1.5-5.75 M3D) of ultra pure demineralized water. Simply plug into your watermaker to The UltroClear DF system works with the Aqua get endless spot-free rinse water for Matic to produce water that is double purified. It’s reliable piping connection allows direct feed your boat.