6.3 Mounting the outdoor unit
6.3.1 About mounting the outdoor unit
6.3.2 Precautions when mounting the outdoor unit
6.3.3 To provide the installation structure
RXF50~71D5V1B
R32 split series
4P519439-15Q – 2021.10
When
The outdoor and indoor unit must be mounted before the refrigerant piping can be
connected.
Typical workflow
Mounting the outdoor unit typically consists of the following stages:
1
Providing the installation structure.
2
Installing the outdoor unit.
3
Providing drainage.
4
Preventing the unit from falling over.
INFORMATION
Also read the precautions and requirements in the following chapters:
▪
"2 General safety
▪
"6.1 Preparing the installation
Check the strength and level of the installation ground so that the unit will not
cause any operating vibration or noise.
Use a vibration-proof rubber (field supply) in cases where vibrations may be
transmitted to the building.
Fix the unit securely by means of foundation bolts in accordance with the
foundation drawing.
Prepare 4 sets of M8 or M10 anchor bolts, nuts and washers (field supply).
3×
1
2
1
4
precautions" [
5]
4
site" [
26]
6
Unit installation
|
2
2
Installer reference guide