14
|
Maintenance and service

14.4 About the compressor

Installer reference guide
62
Heat exchanger
The heat exchanger of the outdoor unit can get blocked up due to dust, dirt,
leaves, etc. It is recommended to clean the heat exchanger yearly. A blocked
heat exchanger can lead to too low pressure or too high pressure leading to
worse performance.
When servicing the compressor keep in mind following precautions:
DANGER: RISK OF ELECTROCUTION
Use this compressor on a grounded system only.
Turn the power off before servicing the compressor.
Reattach the switch box cover and service lid after servicing.
CAUTION
Always wear safety goggles and protective gloves.
DANGER: RISK OF EXPLOSION
Use a pipe cutter to remove the compressor.
Do NOT use the brazing torch.
Use approved refrigerants and lubricants only.
DANGER: RISK OF BURNING/SCALDING
Do NOT touch the compressor with bare hands.
RXF50~71D5V1B
R32 split series
4P519439-15Q – 2021.10