Restrictions On Adding Expansion Rack 2 - Fujitsu M10 Product Notes

Hide thumbs Also See for M10:
Table of Contents

Advertisement

2.
If the crossbar box to be replaced is the master cabinet, execute the switchscf
command to switch it to standby.
XSCF> switchscf -y -t Standby
3.
The master XSCF is switched. Log in to the XSCF again.
4.
Power off the physical partition (PPAR) that uses the crossbar box, and then
power off the crossbar box to be replaced.
Confirm that the Power-LED on the operation panel of the crossbar box is turned
off.
5.
Disconnect the input power supply to the crossbar box to be replaced, and
replace it.
Note - Although error logs for the crossbar box to be replaced are registered when the input
power supply is disconnected, ignore all of them.
6.
Connect the power cord of the crossbar box to the input power supply.
For details, see "5.4 Connecting Cable to Crossbar Box" in the SPARC M10
Systems Installation Guide.
Wait until STANDBY-LED on the operation panel of the crossbar box turns on.
7.
Execute the diagxbu command to perform diagnosis of the newly installed
crossbar box.
XSCF> diagxbu -y -b XX -t YY -t ZZ
Specify the BB_IDs (00 to 15) of SPARC M10-4S that is powered off in XX, YY,
and ZZ.
8.
Execute the showlogs command to confirm that no error occurred during the
diagnosis.
XSCF> showlogs error
9.
Confirm that there are no faulty components.
XSCF> showstatus

Restrictions on adding expansion rack 2

Addition of a crossbar box using the addfru(8) command is not supported at present.
To add a crossbar box, see the "8.4 Adding the Expansion Rack 2" in the SPARC M10
Systems Installation Guide and read Steps 17 and 18 as follows:
Fujitsu M10/SPARC M10 Systems Product Notes for XCP Version 2043 ・ October 2013