Vent Termination Restrictions; Direct Vent - Urbana U37GI Installation Manual

Table of Contents

Advertisement

D
v
:
iRect
ent
WARNING:
- Follow the venting instructions exactly for safe and proper appliance operation.
- Use Mill Pac or high temp RTV silicone for all venting connections.
- Risk of fire, explosion, or asphyxiation if improper venting setup.
-Risk of fire, do not allow loose materials or insulation to contact vent pipe. Remove
insulation to allow installation of thimble and maintain clearances to combustible
materials.
This appliance uses either a 8" x 11" or 5" x 8" vent pipe system. For safe and proper operation of the
appliance follow the venting instructions exactly. Deviation from the minimum vertical length can create
difficulty in burner start-up and sooting. Allow several minutes for the flame to stabilize after ignition under
extreme vent configurations. It is recommended for vent lengths that pass through unheated spaces
(garages, attics, crawl spaces) be insulated to minimize condensation. Use at least three (3) screws at each
vent connection. Check periodically that the vents are unrestricted, especially the exterior vent cap.
v
t
R
ent
eRmination
D E
B
L
F
Letter
Canadian Installation
A
B
12 in (30 cm)
C
D
E
F
G
H
3 ft (91 cm) within a height of
15 ft (4.5 m) above the meter/
regulator assembly
I
3 ft (91 cm)
Initial Installation
QUALIFIED INSTALLERS ONLY
:
estRictions
B
C
B
Fixed
Closed
Fixed
Openable
Closed
Openable
J
B
A
Termination Cap
Air Supply Inlet
Figure 56: Vent Termination Restrictions, refer to Table 2
Table 2: Vent Termination Clearances
1
US Installation
12 in (30 cm)
9 in (23 cm)
12 in (30 cm)*
30 in (76.2 cm)
12 in (30 cm)
7 in (17.8 cm)
3 ft (91 cm) within a height of
15 ft (4.5 m) above the meter/
regulator assembly*
3 ft (91 cm)*
H
G
I
G
Gas Meter
Restriction Zone
(Termination not allowed)
2
Clearance above grade, verandah, porch, deck, or balcony.
Clearance from window or door that may be opened.
Clearance from permanently closed window (to prevent
condensation).
Vertical clearance to ventilated soffit located above the
terminal, within a horizontal distance of 2 ft (60 cm) from
center line of terminal.
Clearance to unventilated soffit.
Clearance to outside corner.
Clearance to inside corner.
Clearance to each side of center line extended above me-
ter/regulator assembly.
Radial clearance around service regulator vent outlet.
N
O
G
M
K
A
Description
37