Operating Test And Final Checkout Procedure; Startup Procedure - Cleveland Steam Cooker and Rethermalization Unit 22CET3A Operator's Manual

Steam cooker and rethermalization unit
Hide thumbs Also See for Steam Cooker and Rethermalization Unit 22CET3A:
Table of Contents

Advertisement

2. Operating Test and Final Checkout Procedure

The standard Cleveland Range SteamChef
an ON/OFF Control panel.
The ON/OFF works exactly like the manual operation of the timer model except that a selector switch is
used to turn the cooking function from the standby heat mode (OFF) to the cooking mode (ON).
This procedure will evaluate the function of all the major operating controls of the SteamChef
through all steps of this procedure before starting. Complete the Startup Procedure before starting the
actual operating tests. This procedure should be performed only by a service technician or installer.
a. Startup Procedure
(1) Check that the ON/OFF Lever is in the OFF position. There should be no water in the steamer.
(2) Open the steamer door. Remove the slide racks and KleanShield
KleanShield
and pan racks (see Figure 4-9 and 4-10 on Page 25 for installation instructions) and check for
proper installation of the KleanShield , fan guard, slide racks, and door gasket assembly (See
Figure 4-21).
Figure 4-20 Inspecting
Compartment drains
(3) Refer to electrical layout, Figure 4-17, and Table 4-1. Be sure the main power switch is in the
OFF position. Verify installation of the proper size fuses or breakers.
(4) Set the ON/OFF Lever/Switch to the OFF position and open the steamer door.
(5) Remove the right side access cover.
Death, severe electrical shock or equipment damage can result from touching
any component inside unit when main power switch is in the on position. Use
extreme caution during testing with the access cover removed.
(6) Check the internal wiring and make sure there are no loose or disconnected wires. Verify that
the supply wiring is of adequate size and that the unit is properly grounded. Correct any
deficiencies.
3 is equipped with either a manual dial timer control panel or
nor reservoir drains are blocked (See Figure 4-20). Replace the KleanShield
KLEANSHIELD
DRAIN
OPENING AND
OVERFLOW
RESERVOIR
DRAIN
OPENING
WATER
LEVEL
PROBE
WARNING
Figure 4-21 Inspecting Compartment
Interior Accessories
32
3. Read
and check that neither the
REMOVABLE
PAN RACKS
GUARD
KLEANSHIELD
FAN