Troubleshooting - Vacmaster VQ1030SIWDC-110 Original Instructions Manual

Wet and dry vacuum cleaner
Table of Contents

Advertisement

GB
WARNING:
UNPLUG BEFORE TROUBLESHOOTING.
Cleaning Performance
Vacmaster vacuum cleaners are tested for endurance. If your motor is
operating, then the most likely cause for a loss in suction is a blockage or an
opening in the vacuum.
To maintain a high cleaning performance from your machine, it is important
to replace or clean cartridge filters as necessary. Replace full dust bags to
prevent performance drops. A performance drop with clean filters can only be
caused by a blockage in the tools or the hose.
PROBLEM
The appliance does
not work.
Dust is escaping from
the motor cover.
Power tool take-off
socket does not work.
Low suction power and
high operating noise /
vibrations.

TROUBLESHOOTING

TO REDUCE THE RISK OF ELECTRIC SHOCK-
POSSIBLE CAUSE
No power.
Functional fault in the power cord,
switch, or motor.
The cartridge filter is missing or
damaged.
Misuse the cartridge filter when
wet vacuuming, causing the
damage of cartridge filter.
Misuse the foam filter when dry
vacuuming.
Power tool wattage exceeds max
power.
Incorrect operating mode
selected.
Dust bag is full.
Suction nozzle, hose, or tank inlet
is blocked.
Cartridge filter is blocked.
Float valve has closed.
Check the power supply and fuse.
Have the damaged part checked by
qualified personnel or contact the after
sales helpline.
Put in a cartridge filter or replace it.
Replace the damaged cartridge filter
with a new one when dry vacuuming.
Replace the foam filter with the
cartridge filter.
Check the wattage is compatible with
the power tool take-off socket.
Ensure the switch is moved into
position II.
Replace the dust bag.
Check the suction nozzle, hose, and
tank inlet for obstructions.
Remove the cartridge filter and clean.
Empty the container of any liquid
waste and ensure the float value
located underneath the filter is able to
move freely.