Wiring the Power Source
Warning
Warning
Warning
Warning
Step 1
Ensure that the power is off at the AC or DC circuits.
Locate the circuit breakers, turn them OFF, and lock out the circuit.
Warning
If the power is not off at the AC or DC circuit breaker, do not touch the power-input terminal.
Step 2
Use a Phillips screwdriver to loosen the captive screw on the power-input terminal, and open the cover.
Figure 23: Opening the Power-Input Terminal Cover
The terminal screws labels are on the power-input terminal cover. See the following figure.
Cisco Catalyst IR8340 Rugged Series Router Hardware Installation Guide
40
This product relies on the building s installation for short-circuit (overcurrent) protection. Ensure that
the protective device is rated not greater than: AC: 10 A, DC: 15 A Statement 1005
A readily accessible two-poled disconnect device must be incorporated in the fixed wiring. Statement
1022
Only trained and qualified personnel should be allowed to install or replace this equipment. Statement
1030
Hazardous voltage or energy may be present on power terminals. Always replace cover when terminals
are not in service. Be sure uninsulated conductors are not accessible when cover is in place. Statement
1086