Q3 USER GUIDE

12. Fall Down Detection

"Fall down" is a state that a person who falls down freely.
Powered by the Q3 model built-in 3-axis motion sensor and our excellent algorithm in firmware,
The Q3 device can detect the fall down event with higher accuracy, and reduce the false alerts to
minimum. Please refer to B36 command for details.

13. Loud Speaker

Some users are elders, the loud speaker can help them hear more clearly. Besides the default fixed
volume mode, we provide option to allow the user to set up the self-defined volume by adjusting
the microphone and speaker sensitivities. Please refer to command B32 for details.

14. Power Saving

14.1 Normal Power Saving

Q3 will enter into different working modes automatically for power saving according to different
time interval settings. Based on the 3-axis motion sensor, the device can detect its move/stop state
accurately. The users only need to adjust GPRS uploading time intervals to achieve the excellent
tracking performance and power saving results. In this mode, the device always can respond to the
incoming call and SMS message.
Command to set GPRS tracking time interval
000000,B03,<move time interval>,<stop time interval>
1) 000000: SMS command password, default 000000.
2) <move time interval>: tracking time interval under moving, unit is second, default is 30
seconds
3) <stop time interval>: tracking time interval when the device stops, unit is second, default
30s.
4) No matter what time interval is set, the device can respond to the incoming SOS number
phone call or SMS command message.
SMS command configuration examples
I want to track at every 30 seconds always, no
matter this device moves or stops
I want to track at every 24 hours
I want to track at 30 seconds while the device
moves, track at every 3600 seconds while the
device stops
I want to track at every 300 seconds while the
device moves, disable the data uploading while
000000,B03,30,30
000000,B03,86400,86400
000000,B03,30,3600
000000,B03,300,0