Technical description

5.1
Function
The device is equipped with an automatic flame monitoring device which automati-
cally interrupts the gas supply after approx. 20 seconds if the flame goes out.
5.2
Specifications for the different models
The devices are available in different versions:
• PI8022: Cooktop with two burners and safety glass cover
• CE99-DF: Cooktop with three burners and safety glass cover
• CE99-ZF: Cooktop with two burners and safety glass cover
The safety glass cover can be used as a work surface when it is closed.
5.3
Control panel
See fig. 1, page 3
6

Installing the device

The assembly and installation of the gas connection must be performed
by a qualified person who has demonstrated skill and knowledge related
to the construction, installation and operation of gas appliances and has
received safety training to identify and avoid the hazards involved.
For proper operation of your cooking device:
• The cabinet must be
– Properly constructed.
– Squared to the countertop and cabinet face
• The opening in cabinet must be
– Level from side to side and front to rear
• The cabinet opening must be constructed so that no combustible material can be
placed next to the cooktop sides.
• The maximum depth of cabinets installed above the cooking top must be 13 in
(330 mm).