SPECIFICATION DRAWINGS

KDT-1-T
CLEARANCE REQUIREMENTS TO
COMBUSTIBLE AND
NONCOMBUSTIBLE SURFACES:
Right - 4"
Left - 0
Back - 0
3.50"
89mm
9.31"
236mm
1.56"
40mm
1/2" NPT
CONDENSATE
RETURN
12.25"
311mm
9.88"
251mm
8.13"
207mm
8.00"
203mm
9.38"
238mm
12.50"
318mm
1/2" NPT
STEAM
INLET