Acromag IntelliPack Series User Manual

Acromag IntelliPack Series User Manual

Computation transmitters with process current/voltage inputs
Hide thumbs Also See for IntelliPack Series:

Advertisement

Quick Links

IntelliPack Series 892M/894M
Computation Transmitters With
Process Current/Voltage Inputs
USER'S MANUAL
ACROMAG INCORPORATED
30765 South Wixom Road
Wixom, MI 48393-2417 U.S.A.
Tel: (248) 295-0880
Fax: (248) 624-9234
Copyright 1998, Acromag, Inc., Printed in the USA.
Data and specifications are subject to change without notice.
8500598N

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IntelliPack Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Acromag IntelliPack Series

  • Page 1 Computation Transmitters With Process Current/Voltage Inputs USER’S MANUAL ACROMAG INCORPORATED 30765 South Wixom Road Wixom, MI 48393-2417 U.S.A. Tel: (248) 295-0880 Fax: (248) 624-9234 Copyright 1998, Acromag, Inc., Printed in the USA. Data and specifications are subject to change without notice. 8500598N...
  • Page 2: Table Of Contents

    The information contained in this manual is subject to change without notice. Acromag, Inc., makes no warranty of any kind Table 1: Models Covered in This Manual with regard to this material, including, but not limited to, the...
  • Page 3: Key Intellipack 89Xm Features

    IntelliPack Series 892M/894M Computation Transmitter User's Manual DC Voltage/Current Input ___________________________________________________________________________________________ Key IntelliPack 89XM Features…continued Flexible computation transmitter functionality plus convenient reprogrammability makes this instrument extremely powerful and • useful over a broad range of applications. Input operators for Convenient Scaling to Engineering Units - Input & output addition, multiplication, subtraction, and division are provided.
  • Page 4: Intellipack Serial Port Adapter

    For repairs to a product damaged in will require that the transmitter be reconfigured to suit your needs. shipment, refer to the Acromag Service Policy to obtain return This is accomplished with Acromag’s user-friendly Windows instructions. It is suggested that salvageable shipping cartons ...
  • Page 5: Jumper Installation (Voltage Output)

    IntelliPack Series 892M/894M Computation Transmitter User's Manual DC Voltage/Current Input ___________________________________________________________________________________________ Jumper Installation (Voltage Output) WARNING: Explosion Hazard - Substitution of any components may impair suitability for Class 1 Division 2. For voltage output, a short jumper must be installed between the output “I+”...
  • Page 6: Module Configuration

    IntelliPack Series 892M/894M Computation Transmitter User's Manual DC Voltage/Current Input ___________________________________________________________________________________________ Table 3A: IntelliPack 89xM Math Operators 3.0 MODULE CONFIGURATION OPERATOR DESCRIPTION Add (Do Not + Use To Indicate Polarity) This computation transmitter needs to be configured for your Subtract or unary minus for constants application.
  • Page 7: Theory Of Operation

    IntelliPack Series 892M/894M Computation Transmitter User's Manual DC Voltage/Current Input ___________________________________________________________________________________________ Table 3B: IntelliPack 89xM Math Functions…continued IF(OR(A>=B,A=D)) THEN(A) ELSE(C) - 12.56 FUNCTION DESCRIPTION When formulating an equation or response, it is important to OR(n1,n2,..,n5) Conditional construct OR of two to five keep the limits of module resolution in mind (see Table 5).
  • Page 8: Service And Repair

    Transmitters are color coded with a white label. The prefix “8” configuration parameter (zero, full-scale, setpoint, deadband, etc) denotes the IntelliPack Series 800, while the “M” suffix specifies verification. Since Surface Mounted Technology (SMT) boards that this device is primarily a computation (Math) transmitter.
  • Page 9: Analog Output Specifications

    IntelliPack Series 892M/894M Computation Transmitter User's Manual DC Voltage/Current Input ___________________________________________________________________________________________ General Input Specifications ANALOG OUTPUT SPECIFICATIONS Input Accuracy: Better than 0.05% of input span, typical. Better than 0.3% of input span, typical for 0-1mA range. These units contain an optically isolated DAC (Digital-to-Analog This includes the effects of repeatability, but not sensor Converter) that provides a process current or voltage output.
  • Page 10: Approvals

    RJ11 6-wire phone jack). See Drawing 4501-721 for location. Configuration information is downloaded from the host computer through one of its EIA232 serial ports. This port must be connected to the module through an Acromag IntelliPack Serial Port Adapter. This Serial Port Adapter - 10 -...
  • Page 11: Software Configuration

    IntelliPack Series 892M/894M Computation Transmitter User's Manual DC Voltage/Current Input ___________________________________________________________________________________________ serves as an isolated interface converter between EIA232 (ATAN( )). Support for IF-THEN-ELSE, plus AND & OR, >, and the IntelliPack’s SPI port. >=, <, <=, =, <> constructs are included.
  • Page 12: Simplified Schematic (4501-717)

    IntelliPack Series 892M/894M Computation Transmitter User's Manual DC Voltage/Current Input ___________________________________________________________________________________________ - 12 -...
  • Page 13: Functional Block Diagram (4501-718)

    IntelliPack Series 892M/894M Computation Transmitter User's Manual DC Voltage/Current Input ___________________________________________________________________________________________ - 13 -...
  • Page 14: Computer To Intellipack Connections (4501-721)

    IntelliPack Series 892M/894M Computation Transmitter User's Manual DC Voltage/Current Input ___________________________________________________________________________________________ - 14 -...
  • Page 15: Electrical Connections (4501-719)

    IntelliPack Series 892M/894M Computation Transmitter User's Manual DC Voltage/Current Input ___________________________________________________________________________________________ I 4 + V4 + VO LTAG E O UTPUT J UM PER J M P I 3 + V3 + SHL D I 2 + V2 + CO M...
  • Page 16: Enclosure Dimensions (4501-720)

    IntelliPack Series 892M/894M Computation Transmitter User's Manual DC Voltage/Current Input ___________________________________________________________________________________________ (118.9) 4.68 (95.3) 3.75 (59.4) 2.34 - 16 -...
  • Page 17 IntelliPack Series 892M/894M Computation Transmitter User's Manual DC Voltage/Current Input ___________________________________________________________________________________________ Revision History The following table details the revision history for this document: Release Date Version EGR/DOC Description of Revision 03 AUG 2017 CAP/JAA Remove CE Mark due to non-RoHS compliant part. Refer to ECN# 17G016.