Acromag IntelliPack 895M Series User Manual

Frequency output transmitters with process current/voltage inputs
Hide thumbs Also See for IntelliPack 895M Series:

Advertisement

Quick Links

IntelliPack Series 895M/896M
Frequency Output Transmitters With
Process Current/Voltage Inputs
USER'S MANUAL
ACROMAG INCORPORATED
30765 South Wixom Road
Wixom, MI 48393-2417 U.S.A.
Tel: (248) 624-1541
Fax: (248) 624-9234
Email:
sales@acromag.com
Web: http://www.acromag.com
Copyright 1999, Acromag, Inc., Printed in the USA.
Data and specifications are subject to change without notice.
8500606F

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IntelliPack 895M Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Acromag IntelliPack 895M Series

  • Page 1 USER’S MANUAL ACROMAG INCORPORATED 30765 South Wixom Road Wixom, MI 48393-2417 U.S.A. Tel: (248) 624-1541 Fax: (248) 624-9234 Email: sales@acromag.com Web: http://www.acromag.com Copyright 1999, Acromag, Inc., Printed in the USA. Data and specifications are subject to change without notice. 8500606F...
  • Page 2: Table Of Contents

    Table 1. Supplementary sheets are attached for units with special options or features. The information contained in this manual is subject to change Table 1: Models Covered in This Manual without notice. Acromag, Inc., makes no warranty of any kind Series/ -Options/Output/ -Factory...
  • Page 3: Key Intellipack 895M/896M Features

    IntelliPack Series 895M/896M Frequency Transmitter User's Manual DC Voltage/Current Input __________________________________________________________________________________________ This module includes open-drain frequency outputs with Another use involves varying pulse-width on-time as a function of optional pullups to +5V built-in. The open-drain frequency output the input signal at any frequency from 1 to 10KHz. The safe, can be used to drive electronic counters (TTL or CMOS) directly compact, rugged, reconfigurable, and reliable design of this (using the internal pullup), or it can be used to drive electro-...
  • Page 4: Accessory Items

    For repairs to a product damaged in Configuration Manual (8500-570). These manuals describe shipment, refer to the Acromag Service Policy to obtain return software operation and various alarm and transmitter functions in instructions. It is suggested that salvageable shipping cartons detail.
  • Page 5: Installation

    Note that input, power, and output terminal blocks are a plug-in will require that the transmitter be reconfigured to suit your needs. type and can be easily removed to facilitate module removal or This is accomplished with Acromag’s user-friendly Windows replacement without removing individual wires. If your input is ...
  • Page 6: Module Configuration

    Configuration return (HRTN) terminals of the module to hold the   is done using Acromag’s Windows 95/98 or NT IntelliPack transmitter’s corresponding output at the last value while Configuration Program and Serial Port Adapter. Additional...
  • Page 7 IntelliPack Series 895M/896M Frequency Transmitter User's Manual DC Voltage/Current Input __________________________________________________________________________________________ The 895M/896M will mathematically combine the scaled input All scaling and computation is performed using single precision, signal value(s) according to a preprogrammed output equation floating point arithmetic. A simulator is provided to check scaling entered via the IntelliPack Configuration Software.
  • Page 8 IntelliPack Series 895M/896M Frequency Transmitter User's Manual DC Voltage/Current Input __________________________________________________________________________________________ The computed output value in engineering units, is then scaled to Table 3B: IntelliPack 896M/895M Math Functions output frequency (Hz or CPH), or duty cycle (%), using the zero FUNCTION DESCRIPTION and full-scale frequency endpoints of the desired output range, or...
  • Page 9: Theory Of Operation

    Since Surface Mounted Technology (SMT) boards are generally difficult to repair, it is highly recommended that a non-functioning or simplified further module be returned to Acromag for repair. The board can be C=OR((A>50), AND(C=1, A>48)) damaged unless special SMT repair and service tools are used.
  • Page 10: Specifications

    If the “Run” LED continues to flash, then this is indicative of a -0800: The four digits of this model suffix represent the following problem. In this case, use the Acromag IntelliPack Configuration options, respectively: Software to reconfigure the module or download its firmware and 0 = Relay: No Alarm Relay;...
  • Page 11: Output Specifications

    IntelliPack Series 895M/896M Frequency Transmitter User's Manual DC Voltage/Current Input __________________________________________________________________________________________ Input Scaling: The configuration software is used to scale Frequency Output Specifications: These are open-drain the nominal input signal range endpoints indicated, to frequency outputs whose duty-cycle or frequency is controlled via values representative of the your application’s a pre-programmed control equation.
  • Page 12: Enclosure/Physical Specifications

    IntelliPack Series 895M/896M Frequency Transmitter User's Manual DC Voltage/Current Input __________________________________________________________________________________________ Be careful when making earth ground connections that Table 8A: 896M Supply Current hold return (HRTN) is not tied to earth ground, which may Supply Supply Current Supply Current be connected to input RTN.
  • Page 13: Status Indicators

    EIA232 serial ports. This port width (ON-time) of the resultant output waveform is must be connected to the module through an Acromag modulated from 0% to 100% via the output equation. IntelliPack Serial Port Adapter. This Serial Port Adapter...
  • Page 14 IntelliPack Series 895M/896M Frequency Transmitter User's Manual DC Voltage/Current Input __________________________________________________________________________________________ Input Calibration Zero Engineering Units Value (Inputs and Outputs): The zero engineering units value is the scaled input or output Input Calibration - Low (Each Input): This value is the low endpoint or zero of the configured input range and must value in engineering units that is to correspond to the zero precisely match the applied input signal level upon...
  • Page 15: Simplified Schematic (4501-741)

    IntelliPack Series 895M/896M Frequency Transmitter User's Manual DC Voltage/Current Input __________________________________________________________________________________________ - 15 -...
  • Page 16: Functional Block Diagram (4501-743)

    IntelliPack Series 895M/896M Frequency Transmitter User's Manual DC Voltage/Current Input __________________________________________________________________________________________ - 16 -...
  • Page 17: Computer To Intellipack Connections (4501-747)

    IntelliPack Series 895M/896M Frequency Transmitter User's Manual DC Voltage/Current Input __________________________________________________________________________________________ CONTROL STATUS - 17 -...
  • Page 18: Electrical Connections (4501-744)

    IntelliPack Series 895M/896M Frequency Transmitter User's Manual DC Voltage/Current Input __________________________________________________________________________________________ OUTPUT2 FRQ2 470 OHM OUTPUT1 FRQ1 470 OHM SW2- SW2+ HLD1 HLD2 SW1- HRTN SW1+ FRQ2 PUL2 FRQ1 PUL1 CONTROL STATUS - 18 -...
  • Page 19: Enclosure Dimensions (4501-745)

    IntelliPack Series 895M/896M Frequency Transmitter User's Manual DC Voltage/Current Input __________________________________________________________________________________________ (118.9) 4.68 (95.3) 3.75 CONTROL STATUS (59.4) 2.34 - 19 -...
  • Page 20: Factory Configuration Order Form (8500-592)

    IntelliPack Series 895M/896M Frequency Transmitter User's Manual DC Voltage/Current Input __________________________________________________________________________________________ - 20 -...
  • Page 21: Revision History

    IntelliPack Series 895M/896M Frequency Transmitter User's Manual DC Voltage/Current Input __________________________________________________________________________________________ Revision History The following table details the revision history for this document: Release Date Version EGR/DOC Description of Revision 3-AUG-2017 CAP/JAA Remove CE Mark due to non-RoHS compliant part. Refer to ECO# 17G016. - 21 -...

Table of Contents