Click "Floor heating" in configuration page, as shown in Figure 7-1. This page includes the
following setting items for floor heating/cooling:
① Basic information: edit the remark, type, control type and temperature display of floor
heating/cooling.
② Mode: enable/disable modes, and edit the temperature for corresponding mode. At the
bottom of this part, user may select the default mode when floor heating/cooling is
powered on.
③ Floor heating module setting: to set the information of the floor heating module (Drag the
device in the list of added devices on the right can add floor heating/cooling as well.
Please refer to
④ Temperature range: to set the temperature adjustment range, the minimum and
maximum value can both be set between 5-35℃.
⑤ Relay parameter setting: to set the parameters of floor heating controlled by relay.
⑥ Temperature source: to select the source of the temperature data for floor heating/cooling.
Edit the information of external device if "external" is selected.
⑦ Relay channel setting. Drag the device in the list of added devices on the right can add
floor heating/cooling as well. Please refer to
Notice:
Some of the setting items might be invalid according to the "Control type" selected:
 If "Relay" is selected, Mark ③ is invalid;
 If "Floor heating module" is selected, Mark ② (only enabling/disabling mode is valid, the
mode details are edited on the floor heating module.), ⑤, ⑥ (temperature source can
only be floor heating module) and ⑦ are invalid.
HDL Automation Co., Ltd.
http://www.hdlautomation.com

7 Floor Heating/Cooling Setting

Add Light
for reference).
Granite Display (Buspro) User Manual
Add Light
for reference.
21